In laryngeal high-speed videoendoscopy (HSV) the area between the vibrating vocal folds during phonation is of interest, being referred to as glottal area waveform (GAW). Varying camera resolution may influence parameters computed on the GAW and hence hinder the comparability between examinations. This study investigates the influence of spatial camera resolution on quantitative vocal fold vibratory function parameters obtained from the GAW. In total 40 HSV recordings during sustained phonation (20 healthy males and 20 healthy females) were investigated. A clinically used Photron Fastcam MC2 camera with a frame rate of 4000 fps and a spatial resolution of 512×256 pixels was applied. This initial resolution was reduced by pixel averaging to (1) a resolution of 256×128 and (2) to a resolution of 128×64 pixels, yielding three sets of recordings. The GAW was extracted and in total 50 vocal fold vibratory parameters representing different features of the GAW were computed. Statistical analyses using SPSS Statistics, version 21, was performed. 15 Parameters showing strong mathematical dependencies with other parameters were excluded from the main analysis but are given in the Supporting Information. Data analysis revealed clear influence of spatial resolution on GAW parameters. Fundamental period measures and period perturbation measures were the least affected. Amplitude perturbation measures and mechanical measures were most strongly influenced. Most glottal dynamic characteristics and symmetry measures deviated significantly. Most energy perturbation measures changed significantly in males but were mostly unaffected in females. In females 18 of 35 remaining parameters (51%) and in males 22 parameters (63%) changed significantly between spatial resolutions. This work represents the first step in studying the impact of video resolution on quantitative HSV parameters. Clear influences of spatial camera resolution on computed parameters were found. The study results suggest avoiding the use of the most strongly affected parameters. Further, the use of cameras with high resolution is recommended to analyze GAW measures in HSV data.
机译:在喉头高速视频内窥镜检查(HSV)中,发声期间振动声带之间的区域是令人关注的,称为声门区域波形(GAW)。相机分辨率的变化可能会影响GAW上计算出的参数,因此会影响检查之间的可比性。这项研究调查了空间相机分辨率对从GAW获得的定量声带振动功能参数的影响。共调查了40个持续发声期间的HSV录音(20名健康的男性和20名健康的女性)。使用临床使用的Photron Fastcam MC2相机,其帧速率为4000 fps,空间分辨率为512×256像素。通过将像素平均化为(1)256×128的像素和(2)像素为128×64的像素,可以降低此初始分辨率,从而产生三组记录。提取GAW,并计算出代表GAW不同特征的总共50个声带振动参数。使用SPSS Statistics版本21进行了统计分析。 15主要分析排除了与其他参数具有强烈数学依赖性的参数,但在支持信息中给出了这些参数。数据分析揭示了空间分辨率对GAW参数的明显影响。基本周期措施和周期扰动措施受影响最小。幅度干扰措施和机械措施受到的影响最大。大多数声门动力学特征和对称性测量方法均出现明显偏差。大多数能量摄动措施在男性中发生了显着变化,但在女性中大多数未受影响。在女性中,剩余的35个参数中的18个(51%)和男性中的22个参数(63%)在空间分辨率之间发生了显着变化。这项工作代表了研究视频分辨率对定量HSV参数的影响的第一步。发现了空间相机分辨率对计算参数的明显影响。研究结果表明避免使用受影响最大的参数。此外,建议使用高分辨率的摄像机来分析HSV数据中的GAW量度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号