首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Comparison of Clinical Performance of Abbott RealTime High Risk HPV Test with That of Hybrid Capture 2 Assay in a Screening Setting
【2h】

Comparison of Clinical Performance of Abbott RealTime High Risk HPV Test with That of Hybrid Capture 2 Assay in a Screening Setting

机译:筛选环境中雅培实时高风险HPV检测与Hybrid Capture 2检测的临床性能比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Randomized trials have produced sound evidence about the efficacy of screening with human papillomavirus (HPV) DNA tests in reducing cervical cancer incidence and mortality. We evaluated the clinical performance and reproducibility of the Abbott RealTime High Risk (HR) HPV test compared with that of the HR hybrid capture 2 (HC2) assay as assessed by a noninferiority score test. A random sample of 998 cervical specimens (914 specimens of cervical intraepithelial neoplasia less severe than grade 2 [<CIN2] and 84 specimens of cervical intraepithelial neoplasia grade 2 or more severe lesions [≥CIN2]), collected in the Florence and Catania cervical Cancer Screening Programs from women aged 25 to 64 and already tested by HR HC2, were retested with the Abbott RealTime HR HPV test. Absolute specificity was 92.3% (95% confidence interval [CI], 90.4 to 94.0) and 92.6% (95% CI, 90.7 to 94.2) for the Abbott RealTime HR HPV test and the HR HC2, respectively. Absolute sensitivity was 96.4% (95% CI, 89.9 to 99.3) and 97.6% (95% CI, 91.7 to 99.7) for the Abbott RealTime HR HPV test and the HR HC2, respectively. The noninferiority score test revealed that the clinical sensitivity and specificity of the Abbott RealTime HR HPV test were not inferior (P = 0.004 and 0.009, respectively) to those of HR HC2. Overall agreement between the two assays was 96.5%, with a k value of 0.86 (CI 95%, 0.82 to 0.91). We evaluated the intralaboratory reproducibility by retesting 521 samples at least 4 weeks after the first test; the crude agreement between the first and second test was 98.5%, with an overall k value of 0.97 (CI 95%, 0.95 to 0.99). This test fully satisfies the requirements of a primary cervical cancer screening test. This assay differentiates between HPV16, HPV18, and non-HPV16/18 types in every specimen, but how to use this information in a screening setting still is unclear.
机译:随机试验已获得可靠的证据,证明了使用人乳头瘤病毒(HPV)DNA检测进行筛查可降低宫颈癌的发病率和死亡率。我们通过非劣性评分测试评估了Abbott RealTime高风险(HR)HPV测试与HR Hybrid Capture 2(HC2)分析相比的临床表现和可重复性。从佛罗伦萨和卡塔尼亚子宫颈癌中收集了998份宫颈标本(其中,重度低于2级[

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号