首页> 美国卫生研究院文献>Journal of Clinical Medicine >Wear in Antagonist Teeth Produced by Monolithic Zirconia Crowns: A Systematic Review and Meta-Analysis
【2h】

Wear in Antagonist Teeth Produced by Monolithic Zirconia Crowns: A Systematic Review and Meta-Analysis

机译:整体式氧化锆冠产生的拮抗牙齿的磨损:系统评价和Meta分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: The aim of this systematic review and meta-analysis was to determine the wear sustained in the natural antagonist tooth in cases of full-coverage fixed-base prosthetic restorations or monolithic zirconia tooth-supported crowns, as well as to determine the wear in the restoration itself, both in the short- and medium-term and considering the factors that may influence wear. Material and methods: A systematic literature review and meta-analysis, based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated wear in antagonist teeth in relation to fixed-prosthesis monolithic zirconia crowns. A total of 5 databases were consulted in the literature search: Pubmed-Medline, Cochrane, Scopus, Embase and Web of Science (WOS). After eliminating duplicated articles and applying the inclusion criteria, eight articles were selected for the qualitative analysis and four for the quantitative analysis. Results: Mean maximum wear of the antagonist tooth in relation to monolithic zirconia crowns of magnitude 95.45 µm (CI at 95% 79.57–111.33) was observed. By using a meta-regression model (R = 0.92) the significant effect of time in maximum wear rate ( < 0.001) was observed, estimated at 6.13 µm per month (CI at 95% 3.99–8.27). Furthermore, monolithic zirconia crowns are subject to a mean maximum wear of 58.47 µm (CI 95% 45.44–71.50). By using a meta-regression model (R = 0.53) the significant effect of time in the maximum wear value was observed ( = 0.053), estimated at 3.40 µm per month (CI al 95% −0.05–6.85). Conclusions: Monolithic zirconia crowns lead to a progressive maximum wear of the antagonist tooth over time which is greater than the maximum wear sustained in the crown itself. It is not possible to establish an objective and quantitative objection in relation to natural enamel wear or metal–ceramic crowns.
机译:背景:本系统综述和荟萃分析的目的是确定在全覆盖固定基义齿修复体或整体氧化锆牙齿支撑牙冠的情况下,天然拮抗牙承受的磨损,并确定牙本质的磨损。在短期和中期,并考虑可能影响磨损的因素,修复体本身。材料和方法:根据系统评价和荟萃分析的首选报告项目(PRISMA)的建议,进行系统的文献综述和荟萃分析,以评估与固定假体整体式氧化锆牙冠相关的拮抗剂牙齿磨损的临床研究。在文献检索中总共查询了5个数据库:Pubmed-Medline,Cochrane,Scopus,Embase和Web of Science(WOS)。在消除重复的文章并应用纳入标准后,选择了八篇文章进行定性分析,选择了四篇进行定量分析。结果:观察到相对于整体氧化锆冠的大小为95.45 µm(CI为95%的79.57-111.33),对齿的平均最大磨损。通过使用元回归模型(R = 0.92),可以观察到时间对最大磨损率(<0.001)的显着影响,估计为每月6.13 µm(CI为95%,3.99–8.27)。此外,整体式氧化锆冠的平均最大磨损为58.47 µm(CI 95%45.44–71.50)。通过使用元回归模型(R = 0.53),观察到时间对最大磨损值的显着影响(= 0.053),估计为每月3.40 µm(CI al 95%-0.05–6.85)。结论:整体式氧化锆冠会导致对齿随着时间的推移逐渐出现最大磨损,这大于冠本身承受的最大磨损。对于天然搪瓷磨损或金属陶瓷冠,不可能建立客观和定量的反对意见。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号