首页> 美国卫生研究院文献>Journal of Sports Science Medicine >Pedometer Accuracy During Stair Climbing and Bench Stepping Exercises
【2h】

Pedometer Accuracy During Stair Climbing and Bench Stepping Exercises

机译:爬楼梯和踏台阶运动时的计步器准确性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of the present investigation was to examine pedometer accuracy during stair climbing and descending as well as during the performance of a bench stepping exercise. Ten healthy men participated in the present investigation. All subjects ascended and descended an 18 cm high public staircase, and performed a bench stepping exercise by using a 10, 20 and 30 cm high platforms, while wearing three different commercial pedometers (DW-800, YM, HJ- 700IT; OM, Lifecorder; KZ). In both situations, the stepping rate was controlled at 40, 50, 80, 100 and 120 steps·min-1. The pedometer scores tended to underestimate the actual number of steps during stair climbing with a slower stepping rate and/or the lower height of a platform. During the stair ascending and descending and the bench stepping exercise using 20 to 30 cm high platforms at 80 to 120 steps·min-1, the magnitude of the measurement error was -3.8 ± 10. 8 % for KZ, -2.1 ± 9.8 % for YM and -11.0 ± 18.9 % for OM. These results indicate that the KZ and the YM can accurately assess the number of steps during stair climbing using 20 to 30 cm high platforms at 80 to 120 steps·min-1.Key points class="unordered" style="list-style-type:disc">Pedometers can assess the number of step accurately within an acceptable range of measurement error during the stair climbing activities at a stepping rate of 80 step·min-1 or faster with 18 cm or higher stairs.
机译:本研究的目的是检查在楼梯爬升和下降以及进行卧推运动期间的计步器准确性。十名健康男性参加了本次调查。所有受试者都上升和下降了一个18厘米高的公共楼梯,并通过使用10、20和30厘米高的平台进行了台阶锻炼,同时穿着三种不同的商业计步器(DW-800,YM,HJ-700IT; OM,Lifecorder ; KZ)。在两种情况下,步进速度均控制在40、50、80、100和120步·min -1 。计步器得分往往会以较低的踩踏速度和/或较低的平台高度低估爬楼梯期间的实际步数。在使用20到30厘米高的平台以80到120步·min -1 进行楼梯上升和下降以及卧推时,测量误差的大小为-3.8±10。 KZ,YM为-2.1±9.8%,OM为-11.0±18.9%。这些结果表明,KZ和YM可以使用80至120步·min -1 的20至30 cm高平台准确评估爬楼梯过程中的步数。要点 class =“无序“ style =” list-style-type:disc“> <!-list-behavior =无序前缀-word = mark-type = disc max-label-size = 0-> 计步器可以评估数字爬楼梯活动期间以80步·分钟 -1 或更高的步速(在18厘米或更高的楼梯上)的步速准确地在可接受的测量误差范围内进行测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号