首页> 中文期刊> 《噪声与振动控制》 >空调管路系统的有限元分析及优化设计

空调管路系统的有限元分析及优化设计

     

摘要

针对设计好的空调管路系统振动较大问题,运用Hyper Mesh软件将设计好的空调管路模型划分成高质量的六面体网格.再将划分好的网格模型导入Ansys中进行模态分析,分析计算出前10阶的固有频率和振型.发现1阶固有频率在工作频率附近,分析该阶固有频率的振型并据此提出管路改进的设计方案,使空调管路系统固有频率远离工作频率,避免产生共振.最后对改进前后的结构进行实验对比,得到改进后的结构振幅减小90%的结果.实践表明在空调减振过程中应用Ansys等有限元技术辅助分析很好地提高了效率和准确性.%The large vibration problem of a designed air-conditioner pipeline system is studied. The Hyper Mesh software is applied to divide the designed air-conditioner pipeline model into a refined hexahedral mesh. Then, the model is imported into Ansys to carry out modal analysis, and the natural frequencies and modals of the first 10 orders are calculated. It is found that the first order natural frequency is near the operating frequency. Based on the analysis of the corresponding vibration mode, an improvement scheme is put forward for the pipeline system so that the first natural frequency of the air conditioning pipeline system can keep far away from the operating frequency to avoid the resonance. Finally, the experiment is carried out for the improved structure, and it is found that the amplitude of the vibration of the improved structure is reduced by 90%. The practice shows that the application of Ansys and the finite element technology can effectively improve the efficiency and accuracy in vibration reduction of air conditioners.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信