首页> 外文会议>IEEE Nuclear Science Symposium;Medical Imaging Conference >Ionization Dose and Neutron Induced Photocurrent and Readout Noise in LYSO+SiPM Packages
【24h】

Ionization Dose and Neutron Induced Photocurrent and Readout Noise in LYSO+SiPM Packages

机译:电离剂量和中子诱导Lyso + Sipm封装中的光电流和读出噪声

获取原文

摘要

The barrel timing layer for the CMS HL-LHC precision timing detector will be constructed using LYSO+SiPM modules. The barrel in HL-LHC beam intensities is expected to be exposed under an ionization dose rate of up to 200 rad/h and a neutron flux of up to 3x106neq/cm2/s. We present results from measurements of photocurrent in the LYSO+SiPM packages induced by Co-60 γ-rays and Cf-252 neutrons. The γ-ray induced readout noise is found to be about 30 keV, which is negligible compared to the 4.2 MeV signal from minimum ionization particles. The neutron induced noise is about 7 keV, which is more than a factor of 4 smaller than that from the ionization dose.
机译:CMS HL-LHC精密定时检测器的桶定时层将使用Lyso + SIPM模块构建。 HL-LHC光束强度中的桶预计将在高达200 rad / h的电离剂量速率下暴露,以及高达3×10的中子通量 6 N. eq /厘米 2 / s。 我们呈现由CO-60γ射线和CF-252中子诱导的LySO + SIPM包装中的光电流测量结果。 发现γ射线诱导的读出噪声是大约30keV,与来自最小电离颗粒的4.2mEV信号相比可忽略不计。 中子诱导的噪声约为7keV,比从电离剂量小于4倍。