A Au-Si eutectic vacuum packaging process was evaluated using high sensitivity poly-Si Pirani vacuum sensors. Encapsulation of devices was achieved by bonding a silicon cap wafer to a device wafer using a Au-Si eutectic solder at above 390 °C in a vacuum bonder. The Au-Si eutectic solder encircled the devices, providing an airtight seal. The Pirani gauges were encapsulated and tested over a period of several months in order to determine base pressures and leak/outgassing rates of the micro-cavities. Packaged devices without getters showed initial pressures from 2 to 12 Torr with initial leak/outgassing rates of -0.073 to 80 Torr/year. Using getters, pressures as low as 5 mTorr have been achieved with leak/outgassing rates of <10 mTorr/year. Trends in pressure over time seem to indicate outgassing (desorption of atoms from inside of the microcavity) as the primary mechanism for pressure change over time.
机译:使用高灵敏度多Si Pirani真空传感器评估Au-Si共晶真空包装方法。通过在真空粘合剂中在390℃下在390℃下粘合到器件晶片来实现器件的封装。 Au-Si共晶焊料环绕这些装置,提供气密密封。将Pirani测量仪封装并在几个月内进行测试,以确定微空腔的基础压力和泄漏/分散率。没有吸气剂的封装设备显示2到12托的初始压力,初始泄漏/放差率为-0.073至80托/年。使用getters,低至5 mtorr的压力已经实现了<10 mtorr /年的泄漏/放差率。随着时间的推移,压力的趋势似乎表示排出(从微腔内的原子的解吸)作为压力变化随时间的主要机制。