首页> 外文会议>International Workshop on Low Temperature Detectors >Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters
【24h】

Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters

机译:为大量微量微核计的基于TES的Cryo-antivence开发

获取原文

摘要

The employment of large arrays of microcalorimeters in space missions (IXO, EDGE/XENIA)[1][2][3], requires the presence of an anticoincidence detector to remove the background due to the particles, with a rejection efficiency at least equal to Suzaku (98%) [1]. A new concept of anticoincidence is under development to match the very tight thermal requirements and to simplify the design of the electronic chain. The idea is to produce a Cryo-AntiCoincidence (Cryo-AC) based on a silicon absorber and read by a TES (Transition-Edge Sensor). This configuration would ensure very good performances in terms of efficiency, time response and signal to noise ratio. We present the results of estimations, simulations and preliminary measurement.
机译:在太空任务(IXO,Edge / Xenia)[1] [3]中的大阵列的使用大阵列(IXO,Edge / Xenia)[3],需要存在抗煎探测器,以除粒子引起的背景,抑制效率至少相等到苏崎(98%)[1]。在开发中,抗凝结的新概念是为了匹配非常紧张的热量要求,并简化电子链的设计。该思想是基于硅吸收器产生低温 - 抗渗透(Cryo-AC)并由TES(过渡边缘传感器)读取。这种配置将在效率,时间响应和信噪比方面确保非常好的性能。我们介绍了估计,模拟和初步测量结果。