首页> 外文会议>International symposium for Testing and Failure Analysis >Evacuated FM08 Fuses Carry a Sustained Arc in a Bus over 75 VDC
【24h】

Evacuated FM08 Fuses Carry a Sustained Arc in a Bus over 75 VDC

机译:疏散的FM08保险丝在75 VDC中携带持续弧线

获取原文

摘要

The FM08 style fuse is specified to interrupt an overcurrent of up to 300 A in a bus of up to 125 VDC, but this applies only when its barrel is filled with air. When placed into a space-grade vacuum, the FM08 style fuse exhausts its air within a year. Then, the probability of an enduring arc is high for all ratings when the bus is above 75 VDC, and the overcurrent is large. The arc endures until something else interrupts the current. The fuse can violently eject metal vapor or other material during the sustained arcing. The evacuated FM08 does not develop a sustained arc when interrupted in a bus of 38 VDC or less, at least when there is little inductance in the circuit. This is consistent with its successful use in many spacecraft having buses in the range 24 to 36 volts.
机译:指定FM08样式熔丝以中断高达300 A的过电流,最高可达125 VDC,但这仅适用于其枪管充满空气时。当放入空间级真空中时,FM08风格保险丝在一年内耗尽其空气。然后,当总线高于75 VDC时,所有额定额度的持久弧的概率都很高,并且过电流大。电弧持久,直到其他内容中断电流。保险丝在持续的电弧过程中可以振奋地弹出金属蒸汽或其他材料。当在38 VDC或更少的总线中中断时,疏散的FM08至少在电路中的电感很小时,不会产生持续的电弧。这与其在许多航天器中的成功使用符合24至36伏的公共汽车。