Design of a high fill-factor micromachined bolometer for thermal imaging applications

机译:用于热成像应用的高填充系数微机械测辐射热计的设计

获取原文

摘要

This paper reports a novel design of a microchined bolometer for thermal imaging applications. The thermal modeling and stress analysis of infrared radiation bolometer which is made of a thin film of aSi:H has been performed using FLUENT(6.1) and ANSYS (11) CFD programs respectively. This bolometer is realized in a multilevel electro thermal structure having a high fill factor. Using the multilevel structure, thermal isolation can be independently optimized without sacrificing the IR absorption area. The analysis showed that optimization of the arm dimensions can be done without failure of structure breakdown or buckling. The design shows that the thermal time constant is 12.95 ms, the responsivity is of 4.65×103 V/W, and the detcetivity is of 7.97×108 cm Hz1/2 w−1 which can be achieved in a 50μm×50μm michromachined structure
机译:本文报道了一种用于热成像应用的微加工辐射热计的新颖设计。分别使用FLUENT(6.1)和ANSYS(11)CFD程序对由aSi:H薄膜制成的红外辐射热辐射计进行了热建模和应力分析。该辐射热计以具有高填充因子的多级电热结构实现。使用多层结构,可以在不牺牲IR吸收面积的情况下独立优化热隔离。分析表明,可以在不发生结构破坏或屈曲的情况下优化臂的尺寸。设计表明,热时间常数为12.95 ms,响应度为4.65×10 3 V / W,复度为7.97×10 8 cm Hz < sup> 1/2 w -1 可以在50μm×50μm重铬酸盐化的结构中实现