The DARHT-Ⅱ final focusing system consists of a solenoid and a foil, which is used to confine backstreaming ions. The separation between the converter target and the foil needs to be small to minimize the ion focusing effects. The beam spot size on the foil has to be large enough to ensure survivability of the foil while it is being struck by four high current pulses over 2 microsecond period. We have investigated several final focusing lens and focusing schemes. The simulation results of the beam spot size on the target are presented.
机译:DARHT-Ⅱ最终聚焦系统由螺线管和金属箔组成,用于限制回流离子。转换器靶和箔之间的距离必须很小,以使离子聚焦效应最小。箔片上的束斑尺寸必须足够大,以确保箔片在2微秒的时间内被四个高电流脉冲撞击时仍能生存。我们研究了几种最终的聚焦透镜和聚焦方案。给出了目标上束斑尺寸的仿真结果。