Introduction The aim of this study was to assess the long-term performance of a cemented total knee replacement utilising an All Polyethylene Tibial (APT) component and in addition to perform an engineering analysis of any failures to help refine surgical technique. Materials and methods A total of 26 patients had a total knee replacement performed using a cemented Depuy Press Fit Condylar (PFC) APT component and a cruciate retaining femoral component. At final review all patients were assessed using The Knee Society Score together with radiographs. An engineering analysis simulated loading conditions of the implants that failed and these were compared with the performance of a modular metal-backed Tibial (MBT) component. Results A total of 20 patients were reviewed at mean time of 116 months following surgery. Knee Society Knee Scores and Function Scores in this cohort were 84/100 and 58/100, respectively. Two patients required revision for tibial component failure. Pre-operatively both had valgus deformities and in each case the tibial tray had been lateralised leaving a gap on the medial side where the APT component had no rigid support. The engineering analysis demonstrated that the volume of highly strained cancellous bone was greater in the APT design compared with the MBT design when a model with a 3 mm medial gap was loaded. The stiffer MBT base plate acted more rigidly and shielded the stress applied to the proximal tibial cancellous bone. Conclusion The APT component demonstrated satisfactory clinical and radiographic performance at long-term follow up. Appropriate cortical support of the APT component is important. The implant should be used with a degree of caution in patients with severe deformities and osteoporosis.
机译:引言这项研究的目的是评估使用全聚乙烯胫骨(APT)组件进行骨水泥全膝关节置换术的长期性能,并对所有失败进行工程分析以帮助完善外科技术。材料和方法共有26例患者使用胶合的Depuy Press Fit dy突(PFC)APT组件和交叉保留股骨组件进行了全膝关节置换。在最终检查中,所有患者均通过膝关节社会评分和X光片进行评估。工程分析模拟了失败的植入物的负载情况,并将其与模块化金属支撑胫骨(MBT)组件的性能进行了比较。结果共有20例患者在平均116个月的手术时间后接受了检查。膝关节协会该队列的膝关节评分和功能评分分别为84/100和58/100。两名患者因胫骨组件衰竭需要翻修。术前均具有外翻畸形,并且在每种情况下,胫骨托均向外侧倾斜,在内侧没有APT组件的刚性支撑。工程分析表明,当加载内侧间隙为3 mm的模型时,与MBT设计相比,APT设计中的高应变松质骨体积更大。较坚硬的MBT底板作用更牢固,并屏蔽了施加在胫骨近端松质骨上的应力。结论APT组件在长期随访中表现出令人满意的临床和影像学表现。 APT组件的适当皮层支撑很重要。对于严重畸形和骨质疏松的患者,应谨慎使用植入物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号