摘要

The work presented here deals with the development of a quantitative tool for the determination of the quaternary ammonium anticholinergic glycopyrrolate in human plasma samples. Mepenzolate was used as an internal standard. The plasma samples were subjected to a suitable sample clean-up consisting of a simple and relatively fast, two step liquid-liquid ion-pair extraction procedure. The chromatography. using the same volatile ion-pair reagent heptafluorobutyric acid (HFBA), takes only 10 min. Relative standard deviation of retention times was never above 2.26% (n=36). The method was fully validated based on the US FDA Bioanalytical Method Validation Guidance for Industry. As such, a quantitative ESI-LC-MS(/MS) (TOF mass spectrometry) method was optimized for the absolute quantification of glycopyrrolate in human plasma in a concentration range from 0.101 to 101 ng/mL using a quadratic calibration function (R-2 = 0.9995), y = -2.21 x 10(-4) (+/- 3.93 x 10(-5)) x chi(2) + 5.85 x 10(-2) (+/- 5.27 x 10(-3)) x x + 4.08 x 10(-3) (+/- 4.82 x 10(-4)). For the three QC concentrations (QC(1) 0.252, QC(2) 2.52, and QC(3) 25.2 ng/mL) and the LLOQ (0.101 ng/mL), total precision was under 20% (18.0% (n = 6) at the LLOQ) and maximum accuracy was 112% (88.9% for the LLOQ, n = 6). Absolute matrix effect (maximum 133% +/- 9.59, n = 3), absolute recovery (better than 41.8% +/- 2.22, n = 3), relative (inter-subject) matrix effect (maximum 10.9% +/- 1.45, n = 4) and process efficiency (better than 45.2% +/- 5.74, n = 3) too were assessed at the 3 QC concentrations.
机译:本文介绍的工作涉及定量工具的开发,该工具可用于测定人血浆样品中的抗胆碱能格隆溴铵季铵盐。甲苯甲酸酯用作内标。对血浆样品进行适当的样品净化,包括简单且相对快速的两步液-液离子对萃取程序。层析。使用相同的挥发性离子对试剂七氟丁酸(HFBA),只需10分钟。保留时间的相对标准偏差从未超过2.26%(n = 36)。该方法已根据美国FDA工业用生物分析方法验证指南进行了充分验证。因此,优化了定量ESI-LC-MS(/ MS)(TOF质谱)方法,使用二次校准函数(R-,对人血浆中的格隆溴铵在0.101至101 ng / mL的浓度范围内进行了绝对定量2 = 0.9995),y = -2.21 x 10(-4)(+/- 3.93 x 10(-5))x chi(2)+ 5.85 x 10(-2)(+/- 5.27 x 10(-3) ))xx + 4.08 x 10(-3)(+/- 4.82 x 10(-4))。对于三个QC浓度(QC(1)0.252,QC(2)2.52和QC(3)25.2 ng / mL)和LLOQ(0.101 ng / mL),总精度低于20%(18.0%(n = 6)在LLOQ上),最大精度为112%(LLOQ为88.9%,n = 6)。绝对基质效应(最大133%+/- 9.59,n = 3),绝对恢复(优于41.8%+/- 2.22,n = 3),相对(受试者间)基质效应(最大10.9%+/- 1.45 ,n = 4)和过程效率(优于45.2%+/- 5.74,n = 3)也在3个QC浓度下进行了评估。