首页> 美国卫生研究院文献>other >A novel validated procedure for the determination of nicotine eight nicotine metabolites and two minor tobacco alkaloids in human plasma or urine by solid-phase extraction coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry
【2h】

A novel validated procedure for the determination of nicotine eight nicotine metabolites and two minor tobacco alkaloids in human plasma or urine by solid-phase extraction coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry

机译:对于尼古丁的确定一种新的验证过程八种尼古丁代谢物和耦合用液相色谱 - 电喷雾串联质谱在人血浆或尿两个次要烟草生物碱通过固相萃取

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A novel validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) procedure was developed and fully validated for the simultaneous determination of nicotine-N-β-D-glucuronide, cotinine-N-oxide, trans-3-hydroxycotinine, norcotinine, trans-nicotine-1′-oxide, cotinine, nornicotine, nicotine, anatabine, anabasine and cotinine-N-β-D-glucuronide in human plasma or urine.Target analytes and corresponding deuterated internal standards were extracted by solid-phase extraction and analyzed by LC-MS/MS with electrospray ionization (ESI) using multiple reaction monitoring (MRM) data acquisition. Calibration curves were linear over the selected concentration ranges for each analyte, with calculated coefficients of determination (R2) of greater than 0.99. The total extraction recovery (%) was concentration dependent and ranged from 52–88 % in plasma and 51–118 % in urine. The limit of quantification for all analytes in plasma and urine were 1.0 ng/mL and 2.5 ng/mL respectively with the exception of cotinine-N-β-D-glucuronide which was 50 ng/mL. Intra-day and inter-day imprecision were ≤14 % and ≤17 % respectively. Matrix effect (%) was sufficiently minimized to ≤19 % for both matrices using the described sample preparation and extraction methods. The target analytes were stable in both matrices for at least 3 freeze thaw cycles, 24 hours at room temperature, 24 hours in the refrigerator (4 °C) and 1 week in the freezer (−20 °C). Reconstituted plasma and urine extracts were stable for at least 72 hours storage in the liquid chromatography autosampler at 4 °C.The plasma procedure has been successfully applied in the quantitative determination of selected analytes in samples collected from nicotine-abstinent human participants as part of a pharmacokinetic study investigating biomarkers of nicotine use in plasma following controlled low dose (7 mg) transdermal nicotine delivery. Nicotine, cotinine, trans-3-hydroxycotinine and trans-nicotine-1′-oxide were detected in the particular sample presented herein. The urine procedure has been used to facilitate the monitoring of unauthorized tobacco use by clinical study participants at the time of physical examination (before enrolment) and on the pharmacokinetic study day.

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号