The interpolated twitch technique is a widely used method of assessing muscle voluntary activation. The approach involves delivering an electrical stimulus to determine the degree to which a voluntarily activated muscle is activated. If the muscle is not fully activated then additional force will be generated by this stimulus. The amount of additional force generated can be used to quantify the degree of activation. Conventionally, for this technique, stimuli are delivered either manually (when the force reaches a plateau) or after a set time period post onset of contractions. This study examined an approach for interpolated twitch that has recently been suggested to improve precision of the technique. For this method, stimuli were delivered once the force produced by participants reached 97% of their previously recorded maximum voluntary isometric contraction force. This method was used to examine quadriceps activation in 15 male volunteers. Muscle activation was determined using two different methods of stimulus delivery. One method involved the stimulus being automatically triggered when participant’s knee extension force reached 97% of their maximum voluntary isometric contraction. The other method involved the stimulus being manually delivered when the force tracing reached a plateau. The purpose of the study was to verify that this automatic force based triggering method improved the precision in delivering stimuli near peak force. Also, the quadriceps voluntary activation determined using both stimulus delivery approaches were compared. The findings indicated that the automatic force based triggering method reduced the stimulus delivery timing errors by 119% and increased voluntary activation levels by 3% on average. In conclusion, automatic force based triggering is suggested as an alternative approach to stimulus delivery when using interpolated twitch to assess voluntary isometric muscle activation.
机译:内插抽搐技术是评估肌肉自愿激活的一种广泛使用的方法。该方法涉及传递电刺激以确定自愿激活的肌肉被激活的程度。如果肌肉没有完全激活,则该刺激将产生额外的力。所产生的附加力的大小可用于量化激活程度。常规地,对于该技术,刺激是手动地(当力达到平稳时)或在收缩开始后的设定时间段之后传递的。这项研究检查了一种内插抽搐方法,最近已提出该方法以提高该技术的精度。对于这种方法,一旦参与者产生的力达到其先前记录的最大自愿等距收缩力的97%,就会传递刺激。该方法用于检查15位男性志愿者的股四头肌激活情况。使用两种不同的刺激传递方法确定肌肉激活。一种方法是,当参与者的膝盖伸展力达到其最大自愿等距收缩的97%时,自动触发刺激。另一种方法是在力追踪达到平稳状态时手动传递刺激。该研究的目的是验证这种基于自动力的触发方法可以提高在接近峰值力时传递刺激的精度。此外,比较了使用两种刺激传递方法确定的股四头肌自愿激活。研究结果表明,基于自动力的触发方法平均减少了119%的刺激传递时间误差,并使自愿激活水平平均提高了3%。总之,当使用内插抽搐评估自愿等距肌肉激活时,建议基于自动力触发作为刺激传递的替代方法。

著录项

  • 作者

    Hong Xi;

  • 作者单位
  • 年度 2014
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号