首页>
外文OA文献
>Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT
【2h】
Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT
展开▼
机译:眼前节OCT对前房角暗光变化的动态分析
展开▼
免费
页面导航
摘要
著录项
引文网络
相似文献
相关主题
摘要
PURPOSE. To describe the use of anterior segment optical coherence tomography (OCT) in studying the dynamic dark-light changes of the anterior chamber angle. METHODS. Thirty-seven normal subjects with open angles on dark-room gonioscopy and 18 subjects with narrow angles were analyzed. The dynamic dark-light changes of the anterior-chamber angle were captured with real-time video recording. The angle opening distance (AOD500) and trabecular iris space area (TISA500) of the nasal angle and the pupil diameter in each of the representative serial images were measured. Linear regression analysis was performed to investigate the association between AOD500/TISA500 and pupil diameter. Demographic and biometry measurements associated with the AOD difference (AOD500 (light) - AOD500 (dark)) and TISA difference (TISA500 (light) - TISA500 (dark)) were analyzed with univariate and multivariate regression models. RESULTS. The AOD500/TLSA500 measured in the light in the open-angle and the narrow-angle groups were 694 ± 330 μm/0.24 ± 0.10 mm 2 and 265 ±78 μm/0.10 ± 0.03 mm 2, respectively. These values were significantly greater than the AOD500/TISA500 measured in the dark (492 ± 265 μm/0.16 ± 0.08 mm 2 and 119 ± 82 μm/0.05 ± 0.04 mm 2, respectively, all with P 0.001). The ranges of the AOD/TISA difference were 13 to 817 μm/0.011 to 0.154 mm 2, with an average of 180 μm/0.073 mm 2. Multivariate regression analysis identified a positive correlation between anterior chamber depth and the AOD/TISA difference. Fifty eyes showed significant correlations between AOD/TISA and pupil diameter, whereas one eye showed no association. Four eyes in the narrow angle group developed appositional angle closure in the dark. CONCLUSIONS. The dynamic dark-light changes of the anterior chamber angle can be imaged and analyzed with anterior segment OCT. Although the angle width generally decreased linearly with increasing pupil diameter, the differences of the angle width measured in the dark and in the light varied substantially among individuals.
展开▼
机译:目的。描述前段光学相干断层扫描(OCT)在研究前房角动态暗光变化中的用途。方法。分析了37名在暗室角膜镜检查中有开角的正常受试者和18名具有窄角的受试者。前室角度的动态暗光变化通过实时视频记录来捕获。测量每个代表性连续图像中的鼻角的角张开距离(AOD500)和小梁虹膜间隔区域(TISA500)和瞳孔直径。进行线性回归分析以研究AOD500 / TISA500与瞳孔直径之间的关系。使用单变量和多元回归模型分析了与AOD差异(AOD500(浅)-AOD500(深色))和TISA差异(TISA500(浅)-TISA500(深色))相关的人口统计学和生物统计学测量。结果。在开角组和窄角组的光线下测得的AOD500 / TLSA500分别为694±330μm/ 0.24±0.10 mm 2和265±78μm/ 0.10±0.03 mm 2。这些值显着大于在黑暗中测得的AOD500 / TISA500(分别为492±265μm/ 0.16±0.08 mm 2和119±82μm/ 0.05±0.04 mm 2,所有情况下P <0.001)。 AOD / TISA差异的范围为13至817μm/ 0.011至0.154 mm 2,平均值为180μm/ 0.073 mm2。多因素回归分析确定前房深度与AOD / TISA差异之间呈正相关。五十只眼显示AOD / TISA与瞳孔直径之间存在显着相关性,而另一只眼则没有相关性。窄角组中的四只眼睛在黑暗中形成并置角闭合。结论。前房角的动态暗光变化可以通过前节OCT进行成像和分析。尽管角度宽度通常随着瞳孔直径的增加而线性减小,但是在黑暗和光线下测得的角度宽度之间的差异在各个个体之间会有很大差异。
展开▼