首页> 外文OA文献 >Validity of Wrist-worn Physical Activity Monitors to Measure Heart Rate
【2h】

Validity of Wrist-worn Physical Activity Monitors to Measure Heart Rate

机译:腕式运动监​​测仪测量心率的有效性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Numerous physical activity monitors exist and are used to track and improve fitness levels. Due to the increasing popularity of these devices, newer products have been developed that measure heart rate (HR) at the wrist. Little is known about how accurate these devices are at measuring HR at the wrist and how they compare to each other. PURPOSE: To determine how accurately HR was measured by three different wrist-worn physical activity monitors. METHODS: Recreationally active men (n=9) and women (n=3) participated in this study. The average age and weight of participants was 22 ± 3 years and 73.9 ± 12 kg. TomTom Cardio (TT), Fitbit Surge (FB) and Microsoft Band (MB) physical activity monitors were used. The TT, FB, and MB were randomly assigned to the right or left wrist for each participant. The testing procedure included speeds of 2, 3, 4, 5, and 6 mph with each speed lasting three minutes. HR was measured by electrocardiography (ECG) using standard limb lead II and by the three different physical activity monitors. HR was recorded from each device every minute throughout the duration of the procedure. Pearson product moment correlations and bias between electrocardiography (ECG) and physical activity monitors with 95% limits of agreement (Bland-Altman analysis) were calculated. Repeated measures ANOVA [Speed x Device] were also calculated. Statistical significance was set at pRESULTS: At 2 mph and 3 mph, only TT HR was significantly correlated with ECG heart rate (r=0.693, p=0.012 and r=0.592, p=0.043). At 4 mph and 6 mph TT was significantly correlated with ECG (r=0.911, pCONCLUSION: With increasing speeds, physical activity monitors more accurately measure HR but individuals should be aware that these devices may overestimate HR during slower walking speeds.
机译:存在许多体育锻炼监测器,用于监测和提高健康水平。由于这些设备的日益普及,已开发出可测量腕部心率(HR)的新产品。这些设备在测量手腕上的HR的准确性以及如何相互比较方面知之甚少。目的:确定通过三个不同的腕戴式身体活动监测仪测量HR的准确性。方法:娱乐活动的男性(n = 9)和女性(n = 3)参加了这项研究。参与者的平均年龄和体重为22±3岁和73.9±12 kg。使用了TomTom Cardio(TT),Fitbit Surge(FB)和Microsoft Band(MB)身体活动监视器。 TT,FB和MB被随机分配给每个参与者的右手腕或左手腕。测试过程包括2、3、4、5和6 mph的速度,每种速度持续三分钟。通过使用标准肢体铅II的心电图(ECG)和三个不同的身体活动监测器来测量HR。在整个过程中,每分钟都会从每台设备记录HR。计算了心电图(ECG)和具有95%一致性限制的体育活动监测器之间的皮尔逊乘积矩相关性和偏差(Bland-Altman分析)。还计算了重复测量方差分析[Speed x Device]。统计学意义设定为pRESULTS:在2 mph和3 mph时,只有TT HR与ECG心率显着相关(r = 0.693,p = 0.012和r = 0.592,p = 0.043)。在4 mph和6 mph时,TT与ECG显着相关(r = 0.911,p结论:随着速度的提高,身体活动监测仪可以更准确地测量HR,但是个人应该意识到这些设备可能会在慢速行走时过高估计HR。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号