首页> 外文OA文献 >Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers
【2h】

Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers

机译:在单个手指屈曲过程中选择性地招募人类浅指浅屈肌中的单个运动单位

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the ‘test finger’ and that which flexed isometrically was the ‘active’ finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active–test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active–test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.
机译:浅指屈肌(FDS)是一种外在的多肌腱肌肉,可弯曲四个手指的近指指间关节。它包含四个数字组件,每个组件都有一根插入其相应手指上的肌腱。为了确定通过意志选择性地募集这些数字组件的程度,我们通过肌内电极记录了一个组件中单个运动单元的活动,而受试者等轴测地一次弯曲了其余每个手指。该单元主要作用的手指被定义为“测试手指”,而等距弯曲的手指被定义为“活动”手指。记录了79个单位的活性。 50%最大自愿收缩(MVC)的等距手指屈曲力激活的FDS组件中作用于未自愿屈曲的手指的单个单元不到50%。除两个例外,所有涉及食指,中指,无名指和小指测试单位的活动测试手指组合的平均招聘阈值为MVC的49%至60%(其中60%的MVC为未招聘者的价值)。从无名指单位录制时小指弯曲(中位数:MVC为40%),反之亦然(中位数:MVC为2%)。对于所有活动测试手指组合,当活动手指以小于20%的MVC弯曲时,只有35/181个单位被激活,并且其中28个手指相邻。在功能上,要在抓握和提起期间招募FDS单位,需要相对较重的物体,尽管物体的宽度会发生系统性变化。总而言之,FDS组件可以通过意志选择性地激活,这对于用一个或多个手指以较高的力抓握尤其重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号