首页> 外文OA文献 >Development of X-ray fluorescence technique for the uranium determination in Mongolian coal, coal ash, and phosphate ore
【2h】

Development of X-ray fluorescence technique for the uranium determination in Mongolian coal, coal ash, and phosphate ore

机译:X射线荧光技术在蒙古煤,煤灰和磷矿中测定铀的开发

摘要

The results of the determination of uranium in Mongolian brown coal, coal ash, phosphate rock, and technological samples by X-ray fluorescence (XRF) spectrometry are presented. Technological samples were produced from phosphates by chemical treatment. Powder geological samples and Certified Reference Materials (CRMs) were pressed as tablets. For chosen conditions of the sample preparation procedure analytical figures of merit were carefully studied, as exemplified by the rock and uranium ore Reference Materials. The variance of the total uncertainty is 2 % for uranium in the analyzed samples, and one is 7 % in the rock CRMs. The estimated values of the uranium detection limit for the CRMs are within the interval from 1 to 3 ppm. For the correction of the matrix effects the background standard method was used. Values of the uranium contents in the studied samples vary within the interval from 3.0 to 35.0 ppm. The comparison of the wavelength dispersive (WD) XRF results with the energy dispersive (ED) XRF results and the neutron activation analysis (NAA) was performed. It is demonstrated that the WDXRF have satisfactorily agreed with the EDXRF results and the NAA within the limits of the uncertainty. It is shown that the values of the relative discrepancies between the WDXRF and EDXRF results are in the range of 2.0-18.0 %, and between the WDXRF and the NAA results are in the range of 2.0-20.0 %. These values are less than 30 %, yielding the third category of the precision of the mineral raw material analysis.
机译:给出了用X射线荧光(XRF)光谱法测定蒙古褐煤,煤灰,磷矿石和工艺样品中铀的结果。通过化学处理从磷酸盐生产技术样品。将粉末地质样品和经认证的参考材料(CRM)压制成片剂。对于样品制备程序的选定条件,我们仔细研究了品质因数,例如岩石和铀矿石参考材料。分析样品中铀的总不确定度方差为2%,岩石CRM中总不确定度的方差为7%。 CRM的铀检出限的估计值在1-3 ppm的范围内。为了校正基质效应,使用了背景标准方法。研究样品中铀含量的值在3.0至35.0 ppm的范围内变化。将波长色散(WD)XRF结果与能量色散(ED)XRF结果进行比较,并进行中子活化分析(NAA)。事实证明,在不确定性范围内,WDXRF与EDXRF结果和NAA令人满意。结果表明,WDXRF和EDXRF结果之间的相对差异值在2.0-18.0%的范围内,而WDXRF和NAA结果之间的相对差异值在2.0-20.0%的范围内。这些值小于30%,是矿物原料分析精度的第三类。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号