摘要

Today׳s most commonly applied bonding effectiveness tests are criticized for their high variability and low reliability, the latter in particular with regard to measuring the actual strength of the adhesive interface.OBJECTIVES: in continuation of previous research conducted at dentin, we hereby aimed to validate the novel mini-interfacial fracture toughness (mini-iFT) test on its applicability to assess bonding effectiveness of contemporary adhesives when bonded to enamel.METHODS: The 3-step etch&rinse (E&R) adhesive OptiBond FL (Kerr), the 2-step self-etch (SE) adhesive Clearfil SE Bond (Kuraray Noritake) and the two multi-mode adhesives Clearfil S(3) Bond Plus (Kuraray Noritake) and Scotchbond Universal (3M ESPE), both used following a 2-step E&R and 1-step SE mode, were applied to clinically relevant, flattened enamel surfaces. A composite (Filtek Z100; 3M ESPE) build-up was made in layers. After 1-week water storage at 37°C, all specimens were sectioned perpendicular to the interface to obtain rectangular sticks. A mini-iFT notch was prepared at the adhesive-enamel interface using a thin diamond blade under water cooling. Finally, the specimens were loaded in a 4-point bending test until failure.RESULTS: the mini-iFT onto human enamel was significantly higher for the adhesives applied in E&R mode versus those applied in SE mode. The lowest mini-iFT was found for the adhesives applied following a 1-step SE approach. SEM fracture analysis revealed that all fractures originated at the adhesive-enamel interface and that the induced crack propagated preferentially along this interface.CONCLUSION: mini-iFT appeared a valid alternative method to assess the mechanical properties of adhesive-enamel interfaces.
机译:当今最常用的粘合效果测试因其高可变性和低可靠性而受到批评,后者尤其是在测量粘合剂界面的实际强度方面。目的:在牙本质的先前研究的基础上,我们的目的是验证新颖的微界面断裂韧性(mini-iFT)测试是否适用于评估当代胶粘剂与搪瓷的粘合效果。方法:3步蚀刻和冲洗(E&R)胶OptiBond FL(Kerr),2步自蚀刻(SE)粘合剂Clearfil SE Bond(Kuraray Noritake)和两种多模粘合剂Clearfil S(3)Bond Plus(Kuraray Noritake)和Scotchbond Universal(3M ESPE),均按照两步E&R和1进行使用SE模式,应用于临床相关的扁平牙釉质表面。将复合材料(Filtek Z100; 3M ESPE)堆积起来。在37°C下储存1周后,将所有样品垂直于界面切开,以获得矩形棒。在水冷下,使用薄金刚石刀片在胶粘剂-瓷釉界面处制备一个mini-iFT缺口。最后,将样品进行4点弯曲测试直至失效。结果:以E&R模式施用的粘合剂比以SE模式施用的粘合剂上的mini-iFT显着更高。对于采用1步SE方法涂覆的粘合剂,发现最低的mini-iFT。 SEM断裂分析表明,所有断裂均起源于胶粘剂-瓷釉界面,而诱导裂纹优先沿该界面扩展。结论:mini-iFT是评估胶粘剂-瓷釉界面力学性能的有效替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号