首页> 外文OA文献 >An Indirect Atomic Absorption Spectrometric Determination of Trifluoperazine Hydrochloride in Pharmaceutical Formulations Based on Chelate Formation with Palladium(II)
【2h】

An Indirect Atomic Absorption Spectrometric Determination of Trifluoperazine Hydrochloride in Pharmaceutical Formulations Based on Chelate Formation with Palladium(II)

机译:基于螯合物(II)的螯合物形成基于螯合物的药物制剂中三氟吡咯基盐酸盐的间接原子吸收光谱法测定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A new application of an indirect atomic absorption spectrometric (AAS) method was offered for the assay of low concentration of trifluoperazine hydrochloride (TFPH) in pure and pharmaceutical dosage form with good accuracy and precision. The method is depended on the formation of metal complex between the drug (TFPH) and palladium(II) to form orange-yellowish product extractable in organic solvent prior to its aspiration into an air-acetylene flame and indirectly determined by AAS. Using AA responses, all experimental parameters such as, pH, concentration of palladium, reaction time, extraction time and phase ratio which affect the complexation and extraction of TFPH-Pd(II), have been investigated. Under optimized conditions, linearity was observed in the range of 0.5-17 μg mL-1 with detection limit (S/N) of 0.038 μg mL-1, precision in range of 1.18-1.92%, accuracy as the %Erel of 2.4% and recoveries ranged from 101.7 to 104% with mean value of 102.4±0.135. The proposed method was applied for the determination of TFPH in the drug stelazine by both direct calibration and standard additions procedures and found to be 4.88 and 4.87 mg per unite, respectively compared with the stated value of 5 mg per unite. This method is also compared statistically with direct determination by using UV-Vis spectrophotometric technique which is preformed in our laboratory and found to be insignificant at 95% confidence level. All statistical calculations were implemented via the chemsoftware Minitab version 11.
机译:间接原子吸收光谱(AAS)法的新的应用程序被提供在以良好的精度和精度纯和药物剂型三氟盐酸盐(TFPH)的低浓度的测定。该方法依赖于形成金属药物(TFPH)和钯(II)之间的复合物,以形成橙黄色产物萃取在有机溶剂中之前将其抽吸到空气 - 乙炔火焰和间接由AAS确定。使用AA应答,所有的实验参数,例如,pH值,钯的浓度,反应时间,提取时间和相位比影响络合和TFPH - 钯(II)的提取,进行了研究。在优化条件下,在0.5-17微克毫升-1检测限为0.038(S / N)微克ML-1,精度的1.18-1.92%的范围内,精度为2.4%%埃雷尔的范围中观察到的线性度和回收率从101.7至104%之间为102.4±0.135平均值。物通过直接校准和标准添加程序应用于所提出的方法用于TFPH的在药物三氟拉嗪的确定,发现为4.88和每团结4.87毫克,分别与5毫克每凝聚规定值进行比较。这种方法也可以通过使用紫外 - 可见分光光度技术,它是在我们的实验室预制和发现在95%的置信水平显着统计学与直接测定比较。所有的统计计算是通过chemsoftware的Minitab 11版中实现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号