Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients

机译:腕带的光学和胸带心率比较在健康个体和冠状动脉疾病患者的异质样本中

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background The need for unobtrusive HR (heart rate) monitoring has led to the development of a new generation of strapless HR monitors. The aim of this study was to determine whether such an unobtrusive, wrist-worn optical HR monitor (OHRM) could be equivalent and therefore a valid alternative to a traditional chest strap during a broad range of activities in a heterogeneous healthy population and coronary artery disease (CAD) patients. Methods One hundred ninety-nine healthy volunteers, 84 males and 115 females, including 35 overweight-obese subjects, 53 pregnant women, and 20 CAD patients were tested in the present study. Second-by-second HR measured by the OHRM was concurrently evaluated against an ECG-based chest strap monitor during a broad range of activities (i.e., walking, running, cycling, gym, household, and sedentary activities). Results Data coverage, percentage of time the OHRM provides a HR not larger than 10 bpm from the reference, went from a minimum of 92% of the time in the least periodic activity (i.e., gym), to 95% during the most intense activity (i.e., running), and to a maximum of 98% for sedentary activities. The limits of agreement of the difference between the OHRM and the chest strap HR were within the range of ±15 bpm. The OHRM showed a concordance correlation coefficient of 0.98. Overall, the mean absolute error was not larger than 3 bpm, which can be considered clinically acceptable for a number of applications. A similar performance was found for CAD (94.2% coverage, 2.4 bpm error), but the small sample size does not allow any quantitative comparison. Conclusion Heart rate measured by OHRM at the wrist and ECG-based HR measured via a traditional chest strap are acceptably close in a broad range of activities in a heterogeneous, healthy population, and showed initial promising results also in CAD patients.
机译:摘要背景对不引人的人力资源(心率)监测的需求导致开发新一代无肩带HR监视器。本研究的目的是确定这种不引人注目的腕带磨损的光学人力资源管理局(OHRM)是否相当等同,因此在异构健康人群和冠状动脉疾病中广泛的活动期间对传统胸带的有效替代品(CAD)患者。方法在本研究中测试了一百九十九十九个健康志愿者,84名男性和115名女性,其中包括35例超重肥胖的主体,53名孕妇和20名CAD患者。通过OCHRM测量的二秒HR在广泛的活动期间同时评估ECG的胸带显示器(即,走路,跑步,骑自行车,健身房,家庭和久坐活动)。结果数据覆盖范围,OHRM提供的时间百分比从参考中提供不大于10磅的人,从最少的周期性活动(即健身房)的时间至少为92%,而在最激烈的活动期间为95% (即运行),最高98%的久坐活动。 OCRM与胸带HR之间差异的差异的限制在±15bpm的范围内。 OCRM表示一致性相关系数为0.98。总的来说,平均绝对误差不大于3个BPM,这可以在许多应用中被认为是临床上可接受的。发现了类似的性能(94.2%覆盖率,2.4 bpm误差),但小样本尺寸不允许任何定量比较。结论通过传统胸带测量的手腕和ECG的HR测量的心率可接受地在异质,健康的人群中的广泛活动中接近,并且在CAD患者中表现出初步有前途的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号