...
首页> 外文期刊>BMC sports science, medicine & rehabilitation >Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients
【24h】

Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients

机译:健康个体和冠状动脉疾病患者异质样本中手腕佩戴的光学和胸带心率比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background The need for unobtrusive HR (heart rate) monitoring has led to the development of a new generation of strapless HR monitors. The aim of this study was to determine whether such an unobtrusive, wrist-worn optical HR monitor (OHRM) could be equivalent and therefore a valid alternative to a traditional chest strap during a broad range of activities in a heterogeneous healthy population and coronary artery disease (CAD) patients. Methods One hundred ninety-nine healthy volunteers, 84 males and 115 females, including 35 overweight-obese subjects, 53 pregnant women, and 20 CAD patients were tested in the present study. Second-by-second HR measured by the OHRM was concurrently evaluated against an ECG-based chest strap monitor during a broad range of activities (i.e., walking, running, cycling, gym, household, and sedentary activities). Results Data coverage, percentage of time the OHRM provides a HR not larger than 10?bpm from the reference, went from a minimum of 92% of the time in the least periodic activity (i.e., gym), to 95% during the most intense activity (i.e., running), and to a maximum of 98% for sedentary activities. The limits of agreement of the difference between the OHRM and the chest strap HR were within the range of ±15?bpm. The OHRM showed a concordance correlation coefficient of 0.98. Overall, the mean absolute error was not larger than 3?bpm, which can be considered clinically acceptable for a number of applications. A similar performance was found for CAD (94.2% coverage, 2.4?bpm error), but the small sample size does not allow any quantitative comparison. Conclusion Heart rate measured by OHRM at the wrist and ECG-based HR measured via a traditional chest strap are acceptably close in a broad range of activities in a heterogeneous, healthy population, and showed initial promising results also in CAD patients.
机译:背景技术对不显眼的HR(心率)监测的需求导致了新一代无肩带HR监测器的发展。这项研究的目的是确定这种不引人注目的腕戴式光学心率监测仪(OHRM)是否等效,因此在异类健康人群和冠状动脉疾病的广泛活动中可以有效替代传统胸带(CAD)患者。方法对199例健康志愿者,男性84例,女性115例,包括35例超重肥胖者,53例孕妇和20例CAD患者进行了测试。在广泛的活动(即步行,跑步,骑自行车,健身房,家庭和久坐的活动)中,同时使用基于ECG的胸带监测器同时评估了OHRM测得的秒秒HR。结果数据覆盖率(OHRM提供相对于参考的HR不大于10?bpm的时间的百分比)从最少的周期性活动(即体育馆)中的最少92%的时间,变为最剧烈的活动中的95%活动(即跑步),并且久坐活动的最大比例为98%。 OHRM与胸带HR的差异一致的极限在±15?bpm的范围内。 OHRM的一致性相关系数为0.98。总的来说,平均绝对误差不大于3?bpm,在许多应用中可以认为是临床可接受的。对于CAD,发现了类似的性能(94.2%的覆盖率,2.4?bpm的误差),但是样本量小,无法进行定量比较。结论在异类健康人群中,通过手腕上的OHRM测得的心率和通过传统胸带测得的基于ECG的HR在广泛的活动中都可以接受地接近,并且在CAD患者中也显示出初步的有希望的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号