首页> 外文OA文献 >Restoring satisfactory status in ThinPrep Pap test specimens with too few squamous cells and containing microscopic red blood cells
【2h】

Restoring satisfactory status in ThinPrep Pap test specimens with too few squamous cells and containing microscopic red blood cells

机译:恢复诸如鳞状细胞太少细胞和含有微观红细胞的薄皮蛋白拍摄试样中令人满意的状态

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Treatment of specimens that contain excessive blood can effectively reduce the unsatisfactory rate; however, a considerable number of unsatisfactory specimens remain. We evaluated the effectiveness of reprocessing unsatisfactory specimens that had too few squamous cells and contained microscopic red blood cells (TFSQRBC). Out of the 688 unsatisfactory specimens at microscopic screening, 197 (28.63%) were TFSQRBC that were reprocessed by treatment of glacial acetic acid (GAA). Red blood cells were observed clogging the pores in the filter of the ThinPrep device. After reprocessing, 129 (68.48%) yielded a satisfactory diagnosis, which accounted for a reduction of the unsatisfactory rate by 18.25%. In the restored satisfactory specimens, abnormal diagnoses of 1 high-grade squamous intraepithelial lesion (HSIL) (0.78%), 3 atypical glandular cells (AGC) (2.33%), and 13 atypical squamous cells of undetermined significance (ASCUS) (10.08%) were made. The abnormal diagnoses in this group of patients were significantly higher than that in the general population screened. Reprocessing unsatisfactory ThinPrep® (TP) specimens of TFSQRBC can reduce the unsatisfactory rate of the TP Pap test significantly and is a cost-effective measure. The initially unsatisfactory specimens are more likely to represent cases with an abnormal diagnosis, which also justifies the effort of reprocessing this group of specimens. Adjustment of the pore size on the ThinPrep filter device may reduce the interference of red blood cells. Diagn. Cytopathol. 2008;36:696–700. © 2008 Wiley-Liss, Inc.
机译:治疗含有过度血液的标本可以有效降低不令人满意的速率;但是,仍然存在相当数量的不令人满意的标本。我们评估了重新处理鳞状细胞的不令人满意的标本的有效性,并含有微观红细胞(TFSQRBC)。在688个不令人满意的显微筛选标本中,197(28.63%)是通过处理冰醋酸(Gaa)进行再处理的TFSQRBC。观察到红细胞堵塞薄层装置的过滤器中的孔隙。再处理后,129名(68.48%)产生令人满意的诊断,该诊断占减少不满意的税率18.25%。在恢复的令人满意的标本中,1个高档鳞状上皮内病变(HSIL)的异常诊断(0.78%),3个非典型腺细胞(AGC)(2.33%)和13个不确定意义(Ascus)的非典型鳞状细胞(10.08% )是制造的。该组患者的异常诊断显着高于筛选的一般人群。 RFSQRBC的重新处理不令人满意的薄皮®(TP)标本可以显着降低TP PAP测试的不令人满意的速率,并且是一种经济有效的措施。最初不令人满意的标本更有可能代表诊断异常的案例,这也证明了改进这组标本的努力。在薄雾过滤器装置上调整孔径可以减少红细胞的干扰。诊断。细胞质疗法。 2008; 36:696-700。 ©2008 Wiley-Liss,Inc。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号