摘要

This is the final report in a study to demonstrate the feasibility of usingcathodic protection (CP) on concrete bridge structures containing prestressed steel. The interim report, FHWA-RD-95-032, has more details on the installation of selected CP systems. Past laboratory and test yard studies had indicated that overprotection could result in the evolution of atomic hydrogen and the embrittlement of prestressing steel. Systems utilizing catalyzed titanium mesh, conductive rubber, and arc-sprayed zinc anodes were installed on prestressed pilings and girders of the Howard Frankland Bridge in Tampa, Florida; and systems using flame-sprayed zinc and conductive paint anodes were installed on the soffit of prestressed box beams of the Abbey Road and West 130th Street bridges near Cleveland, Ohio.