首页> 外文期刊>Materials Performance >Cathodic Protection Criteria for Prestressed Concrete Pipe-An Update
【24h】

Cathodic Protection Criteria for Prestressed Concrete Pipe-An Update

机译:预应力混凝土管的阴极保护标准 - 更新

获取原文
获取原文并翻译 | 示例
           

摘要

Prestressed concrete cylinder pipe is used in water and wastewater systems that serve virtually every major city in North America. Under certain conditions, such as high chloride environments, steel elements can depassivate, leading to corrosion. Under these conditions, cathodic protection (CP) can be used to protect the encased steel elements. This article provides the results of investigations performed during the past decade to determine the effects of CP on the performance of passivated, corroded, and split prestressing wire immersed in an environment to simulate sound mortar and mortar surrounding severely corroded wire. The current densities required to achieve a 100 mV polarization or depolarization shift and the maximum potential criterion to prevent hydrogen embrittlement (HE) were determined. Also determined were the effect of low pH caused by corroding wire, the susceptibility of prestressing wire to HE, and the approximate length of time and potentials to produce HE and eventual wire failure. The effect of discontinuing high levels of CP on the diffusion of hydrogen from wire and the recovery of ductility were evaluated.
机译:预应力混凝土气缸管用于水和废水系统,几乎所有主要城市都在北美。在某些条件下,例如氯化物环境高,钢元件可以沉积,导致腐蚀。在这些条件下,可以使用阴极保护(CP)来保护包装的钢圈。本文提供了在过去十年中进行的调查结果,以确定CP对钝化,腐蚀和分体式预应力线的性能的影响,浸入环境中,以模拟严重腐蚀的线的声音砂浆和砂浆。确定所需的电流密度,以实现100 mV偏振或去极化移位和最大潜在标准,以防止氢气脆化(HE)。还确定了腐蚀线引起的低pH的效果,预应力线对他的易感性以及产生他和最终失效的近似的时间和潜力。评估了在氢气中停止高水平Cp对氢气扩散的影响及延展性的回收率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号