首页> 美国政府科技报告 >Turbine Blade Wear by Coal Ash in Working Fluid at 1200F
【24h】

Turbine Blade Wear by Coal Ash in Working Fluid at 1200F

机译:120°F工作液中煤灰对涡轮叶片的磨损

获取原文

摘要

A 1,000-hour test with a gas turbine at 1,200 F showed a working fluid of 1 gr of ash per 100 scf of power gas (79 percent of the ash 7 to 35 microns in diameter) to be excessive for acceptable blade wear for commercial practicability. Blades in the turbine consisted of about 20 percent each of chromium, cobalt, and nickel; 3 percent molybdenum; 2-1/2 percent tungsten; and smaller amounts of manganese, columbium, and tantalum. Erosion of both the fronts and backs of the turbine nozzles was particularly heavy, the trailing edges being worn to a featheredge. Erosion of the buckets was less marked, although the leading edges were somewhat pitted. A refractory-lined combustor performed efficiently and with little abrasion of the lining by the ash-laden gas. (Author)