首页> 美国政府科技报告 >Strength of Timber Roof Connections Subjected to Cyclic Loads
【24h】

Strength of Timber Roof Connections Subjected to Cyclic Loads

机译:木材屋顶连接的强度受循环载荷的影响

获取原文

摘要

The investigations described in this report examined the adequacy of typical timber roof connections used in masonry housing construction in resisting forces developed during earthquake ground motions in the less seismically active areas of the United States. Displacement controlled load tests using both in - plane and out - of - plane forces were performed on five basic types of roof - to - masonry wall connection mockups comprising a total of 19 models. The five types of connections contained load - bearing and nonload - bearing connection details of both gabled truss and flat roof construction. Test results indicated that the connection of the truss rafters to bearing and nonbearing walls was adequate. However, supplementary anchorage devices need to be used for connections employing ledgers, since bolts tend to fail by pulling out of the face shell of the masonry units and ledgers fail easily when subjected to cross grain tension. Graphs, drawings, and photographs are used throughout the report and a total of 19 references are provided. (Author abstract modified).

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号