首页> 美国政府科技报告 >Calibration of Photographic and Spectroscopic Films: Reciprocity Failure and Thermal Responses of Iiao Film at Liquid Nitrogen Temperatures
【24h】

Calibration of Photographic and Spectroscopic Films: Reciprocity Failure and Thermal Responses of Iiao Film at Liquid Nitrogen Temperatures

机译:照相和光谱薄膜的校准:液氮温度下Iiao薄膜的互易失效和热响应

获取原文

摘要

Reciprocity failure was examined for IIaO spectroscopic film. The results indicate reciprocity failure occurs at three distinct minimum points in time; 15 min, 30 min and 90 min. The results are unique because theory suggests only one minimum reciprocity failure point should occur. When incubating 70mm IIaO film for 15 and 30 min at temperatures of 30, 40, 50, and 60 C and then placing in a liquid nitrogen bath at a temperature of -190 C the film demonstrated an increase of the optical density when developed at a warm-up time of 30 min. Longer warm-up periods of 1, 2 and 3 hrs yield a decrease in optical density of the darker wedge patterns; whereas, shorter warm-up times yield an overall increase in the optical densities.