...
首页> 外文期刊>Physiological measurement >A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference
【24h】

A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference

机译:对EEG频谱映射的不同参考的比较研究:中性参考的问题和无穷大参考的使用

获取原文
获取原文并翻译 | 示例
           

摘要

Based on EEG data recorded from 11 subjects with eyes open and the left mastoid (M) reference, three data sets were generated by re-referencing to the conventional linked mastoids (L), average (A) and the new 'infinity' (1) reference provided by the reference electrode standardization technique (REST, Yao 2001 Physiol. Meas. 22 693-711). The EEG power in the alpha frequency band with the four different references was calculated and compared with respect to the total energy and spatial amplitude weight centre (AWC) coordinates, to compare the effects of different references on power mapping in the frequency domain. Compared with the I reference, the AWCs of the EEG with the M reference show significant shifts to the right, frontal and superficial positions, the L reference significant shifts to frontal and superficial positions, and the A reference shifts the AWC significantly to a deeper position. Furthermore, the power maps of the M and L references have larger total power than the I reference, while that of the A reference has the smallest total power. These results confirm that different choices of reference electrodes result in systematic changes in the distribution of EEG frequency power, and in order to reduce the effect of such systematic shifts on the explanation of EEG mappings, a common reference is necessary for EEG research. We recommend the I reference for objective use in cross-laboratory studies and clinical practices, as it is far from all the other electrodes and can act as a neutral reference.
机译:根据从11位睁开眼睛的受试者和左乳突(M)参考所记录的脑电数据,通过重新参考常规链接的乳突(L),平均值(A)和新的“无穷大”(1,参比电极由参比电极标准化技术提供(REST,Yao 2001 Physiol。Meas。22 693-711)。计算了具有四个不同参考的α频带中的EEG功率,并相对于总能量和空间幅度权重中心(AWC)坐标进行了比较,以比较不同参考对频域中功率映射的影响。与I参考相比,带有M参考的EEG的AWC显示出向右,额叶和浅表位置的显着偏移,L参考显着转移到额叶和浅表位置,而A参考将AWC显着移至更深的位置。此外,M和L参考的功率图具有比I参考更大的总功率,而A参考的功率图具有最小的总功率。这些结果证实,参比电极的不同选择会导致EEG频率功率分布的系统变化,并且为了减少这种系统偏移对EEG映射的解释的影响,EEG研究需要一个通用参考。我们建议将I参考用于跨实验室研究和临床实践中,因为它与所有其他电极相距甚远,并且可以充当中性参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号