首页> 外文期刊>Ophthalmology >The efficacy, sensitivity, and specificity of in vivo laser confocal microscopy in the diagnosis of meibomian gland dysfunction.
【24h】

The efficacy, sensitivity, and specificity of in vivo laser confocal microscopy in the diagnosis of meibomian gland dysfunction.

机译:体内激光共聚焦显微镜在诊断睑板腺功能障碍中的功效,敏感性和特异性。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To evaluate the efficacy, sensitivity and specificity of confocal microscopy (CM) parameters: meibomian gland (MG) acinar longest diameter (MGALD), MG acinar shortest diameter (MGASD), inflammatory cell density (ICD), and MG acinar unit density (MGAUD) in the diagnosis of MG dysfunction (MGD). DESIGN: Prospective, controlled, single-center study. PARTICIPANTS: Twenty MGD patients (9 males, 11 females; mean age, 63.5+/-16.5 years) and 26 age- and gender-matched control subjects (13 males, 13 females; mean age, 53.2+/-15.7 years) were recruited. METHODS: All subjects underwent slit-lamp examinations, tear film break-up time (BUT) measurements, assessment of tear evaporation rate from the ocular surface (TEROS), vital stainings, Schirmer test, meibography, MG expressibility, and CM of the MG. Data were compared between the 2 groups using the Mann-Whitney and chi-square tests. MAIN OUTCOME MEASURES: The correlation between the clinical findings of tear functions, vital staining scores, and the 4 CM parameters were tested by Spearman's correlation coefficient by rank test. Receiver operating characteristic curve technique was used to evaluate the sensitivity, specificity, and cutoff values of CM parameters. RESULTS: The mean tear film BUT, vital staining scores, TEROS values, MG expressibility, and MG dropout grades by meibography were significantly worse in MGD patients compared with controls (P<0.001). The mean values of the MGALD, MGASD, ICD, and MGAUD in MGD patients were significantly worse than those observed in the controls with CM. All CM parameters showed a strong, significant correlation with tear functions, ocular surface vital stainings, MG expressibility, and MG dropout grades. The cutoff values for MGALD, MGASD, ICD, and MGAUD in the diagnosis of MGD were 65 microm, 25 microm, 300 cells/mm2, and 70 glands/mm2, respectively. The sensitivity and specificity values of these parameters under these cutoff values were 90% and 81% for MGALD, 86% and 96% for MGASD, 100% and 100% for ICD, 81% and 81% for MGAUD. CONCLUSIONS: Confocal microscopy has the potential to diagnose the simple MGD with high sensitivity and specificity. The CM-based diagnostic parameters correlated significantly and strongly with the status of the ocular surface disease. FINANCIAL DISCLOSURE(S): The authors have no proprietary or commercial interest in any of the materials discussed in this article.
机译:目的:评估共聚焦显微镜(CM)参数的功效,敏感性和特异性:睑板腺(MG)腺泡最长直径(MGALD),MG腺泡最短直径(MGASD),炎性细胞密度(ICD)和MG腺泡单位密度(MGAUD)诊断MG功能障碍(MGD)。设计:前瞻性,对照,单中心研究。参与者:20例MGD患者(男9例,女11例;平均年龄63.5 +/- 16.5岁)和26例年龄和性别相匹配的对照受试者(男13例,女性13例;平均年龄53.2 +/- 15.7岁)是被招募。方法:所有受试者均接受裂隙灯检查,泪膜破裂时间(BUT)测量,眼表泪液蒸发率(TEROS)评估,活体染色,Schirmer试验,旋光检查,MG表达和MG CM 。使用Mann-Whitney和卡方检验比较两组之间的数据。主要观察指标:泪液功能的临床表现,活体染色评分和4个CM参数之间的相关性通过Spearman相关系数进行秩和检验。接收器工作特性曲线技术用于评估CM参数的敏感性,特异性和临界值。结果:与对照组相比,MGD患者的平均泪膜BUT,生命染色评分,TEROS值,MG可表达性和MG辍学评分显着降低(P <0.001)。 MGD患者中MGALD,MGASD,ICD和MGAUD的平均值显着低于在CM对照组中观察到的平均值。所有的CM参数均与泪液功能,眼表活体染色,MG的可表达性和MG脱落等级之间有很强的显着相关性。 MGALD,MGASD,ICD和MGAUD在MGD诊断中的临界值分别为65微米,25微米,300细胞/ mm2和70腺/ mm2。在这些临界值下,这些参数的灵敏度和特异性值对于MGALD为90%和81%,对于MGASD为86%和96%,对于ICD为100%和100%,对于MGAUD为81%和81%。结论:共聚焦显微镜具有诊断高灵敏度和高特异性的简单MGD的潜力。基于CM的诊断参数与眼表疾病的状况密切相关。财务披露:作者对本文讨论的任何材料均没有所有权或商业利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号