Personalised assessment of the dose following radioiodine remnant ablation for a patient presenting a residual intrathoracic goitre

机译:放射性碘残留消融后出现残留胸腔内甲状腺肿患者的剂量个性化评估

获取原文
获取原文并翻译 | 示例

摘要

A patient treated with 3.7 GBq of I-131 after thyroidectomy for a papillary carcinoma presented, three days after iodine administration, an unusually elevated dose rate at 1 m. Scintigraphy and Single Photon Emission Computed Tomography coupled with Computed Tomography (SPECT/CT) were performed and showed a significant iodine uptake at the anterior mediastinal level due to the presence of a residual intrathoracic goitre. The proximity between this iodofixant goitre and the surrounding tissues prompted dose estimations to local organs at risk, in particular the heart. Dosimetric estimations were initially performed with OLINDA/EXM software, commonly used in nuclear medicine. More personalised doses were then calculated using the OEDIPE software associated with the Monte Carlo code MCNPX. Calculations with the OLINDA/EXM software enabled a first assessment of the mean absorbed dose to the heart, estimated at about 2 Gy for an uptake of 56% of the administered activity. In a second step, the use of the OEDIPE software allowed us to take into account the specific geometry of the patient as well as the distribution of iodine uptake at a mediastinal level and to determine a mean absorbed dose of approximately 1 Gy to the heart. Thus, the use of a voxelised phantom based on CT images of the patient, associated with direct Monte Carlo calculations, enabled us to improve the calculation of the absorbed doses to the heart compared with the use of a standard anthropomorphic phantom.
机译:碘治疗三天后,甲状腺切除后接受3.7 GBq I-131 I-131治疗的患者出现乳头状癌,其在1 m处的剂量率异常升高。进行了闪烁照相术和单光子发射计算机断层扫描与计算机断层扫描(SPECT / CT)相结合,由于存在残留的胸腔内甲状腺肿,在前纵隔水平上显示出大量的碘吸收。这种碘固色剂甲状腺肿与周围组织之间的接近性促使对处于危险中的局部器官(尤其是心脏)进行剂量估算。剂量估算最初是使用核医学中常用的OLINDA / EXM软件进行的。然后使用与蒙特卡洛代码MCNPX相关的OEDIPE软件计算更多的个性化剂量。使用OLINDA / EXM软件进行的计算可以对心脏的平均吸收剂量进行首次评估,估计吸收的活动量为56%时约为2 Gy。第二步,使用OEDIPE软件可以使我们考虑患者的具体体形以及纵隔水平的碘摄取分布,并确定平均约1 Gy的心脏吸收剂量。因此,基于患者CT图像的体素化体模的使用以及直接的蒙特卡洛计算使我们与标准拟人体模的使用相比,能够改善对心脏吸收剂量的计算。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号