首页> 外文期刊>Radiology >B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: initial experience in humans.
【24h】

B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: initial experience in humans.

机译:空气微泡造影剂在相转化美国的B模式增强:人类的初步经验。

获取原文
获取原文并翻译 | 示例
           

摘要

Pulse- or phase-inversion ultrasonography (US) sums the signals returned from two 180 degrees ultrasound pulses. Linear scattering from tissue results in a signal void while nonlinear signals from microbubbles stand out. The technique was applied with a US contrast agent in 39 human subjects. B-mode enhancement of vessels and organ parenchyma was seen in all cases. Enhancement occurred from flowing and stationary microbubbles. The flow-independent enhancement of normal and abnormal tissue represents a major advance in contrast material-enhanced US with many potential applications especially in tumor imaging.
机译:脉冲或相位反转超声检查(US)将两个180度超声脉冲返回的信号相加。来自组织的线性散射会导致信号无效,而来自微气泡的非线性信号则更为突出。该技术与US造影剂一起应用于39位受试者。在所有情况下均可见血管和器官实质的B型增强。流动和静止的微泡增强。正常和异常组织的不依赖流量的增强代表了造影剂增强型US的重大进步,尤其在肿瘤成像中具有许多潜在应用。