首页> 外文期刊>Nutrition in clinical practice: official publication of the American Society for Parenteral and Enteral Nutrition >Evaluation of fat separation and removal methods to prepare low-fat breast milk for fat-intolerant neonates with chylothorax
【24h】

Evaluation of fat separation and removal methods to prepare low-fat breast milk for fat-intolerant neonates with chylothorax

机译:脂肪分离和去除方法的评估,以制备针对乳糜胸的不耐脂肪新生儿的低脂母乳

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The purpose of this study was to compare 2 methods (syringe and spoon methods) of removing the fat from the low-fat milk portion and compare 3 methods (refrigerated centrifuge, nonrefrigerated centrifuge, and refrigeration method) of separating breast milk into the fat and low-fat milk components. Methods: Human milk was divided into 24 aliquots using the 3 separating methods, and 2 methods (syringe, spoon) were compared to extract the low-fat milk. Thirty-one human milk samples were separated into fatty and low-fat milk layers using 3 methods: 24-hour refrigerator storage (2 C), centrifuged at 3000 rpm for 15 minutes at room temperature, and spun in the refrigerated-centrifuge at 3000 rpm for 15 minutes at 2 C. After 24 hours of refrigeration, a syringe was used to remove the low-fat milk. Triglycerides were analyzed before and after separation and removal methods. Results: For fat removal, the syringe method (1.2 g/dl, 95% confidence interval [CI], 1.1-1.4, fat content) left 34% less residual fat compared to the spoon method (1.9 g/dl, 95% CI, 1.5-2.3); this difference did not reach statistical significance (P =.065). For fat separation, the centrifuge methods (mean: 1.0 g/dl, 95% CI, 0.8-1.1) left significantly less residual fat than the refrigerator method (3.4 g/dl, 95% CI, 3.0-3.7; P <.0001). Conclusion: Using the syringe vs a spoon at removing the milk from the fat, although not statistically significant, was likely of clinical importance. A centrifuge was more effective at separating the fat in human milk.
机译:背景:本研究的目的是比较两种从低脂牛奶中去除脂肪的方法(注射器和勺子方法),并比较三种将母乳分离成低脂牛奶的方法(冷藏离心机,非冷藏离心机和冷藏方法)。脂肪和低脂牛奶成分。方法:使用3种分离方法将人乳分为24等份,并比较2种方法(注射器,勺子)以提取低脂乳。使用以下3种方法将31份人乳样品分为脂肪和低脂乳层:24小时冰箱储存(2 C),在室温以3000 rpm离心15分钟,然后在3000冷冻离心机中离心rpm在2 C下旋转15分钟。冷藏24小时后,使用注射器取出低脂牛奶。在分离和去除方法之前和之后分析甘油三酸酯。结果:为了去除脂肪,注射器法(1.2 g / dl,95%置信区间[CI],1.1-1.4,脂肪含量)比勺法(1.9 g / dl,95%CI)少了34%的残留脂肪。 ,1.5-2.3);这种差异没有达到统计学意义(P = .065)。对于脂肪分离,离心法(平均:1.0 g / dl,95%CI,0.8-1.1)比冷冻法(3.4 g / dl,95%CI,3.0-3.7)残留的脂肪少得多; P <.0001 )。结论:使用注射器和勺子从脂肪中去除牛奶虽然没有统计学意义,但可能具有临床意义。离心机更有效地分离人乳中的脂肪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号