首页> 外文期刊>Neurosurgery >Depth electrode implantation in the length axis of the hippocampus for the presurgical evaluation of medial temporal lobe epilepsy: a computed tomography-based stereotactic insertion technique and its accuracy.
【24h】

Depth electrode implantation in the length axis of the hippocampus for the presurgical evaluation of medial temporal lobe epilepsy: a computed tomography-based stereotactic insertion technique and its accuracy.

机译:在海马长度轴上进行深度电极植入,以对内侧颞叶癫痫进行术前评估:一种基于计算机断层扫描的立体定向插入技术及其准确性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: An individualized computed tomography-based stereotactic technique for the longitudinal insertion of intrahippocampal electrodes is presented and its accuracy described. METHODS: The technique makes use of one well reproducible target in the hippocampal head and of the approximate inclination of the anteroposterior length axis of the hippocampus, for which the orbital floor is taken as an auxiliary landmark. It was used in 141 patients with medically intractable complex partial seizures. In 106 patients, magnetic resonance imaging (MRI) was available for assessment of implantation accuracy. Each of the 212 electrodes was plotted on topographic drawings and its goodness of fit rated. RESULTS: Whereas hippocampal head and body were hit by 97 and 96% of the electrodes, respectively, the amygdala was hit by only 75% of the electrodes and mainly at its basal margin. For 93% of the electrodes, the inclination in a sagittal plane corresponded exactly to that of the hippocampus. The implantation morbidity amounted to 5.7%, whereas permanent neurological deficit occurred in one (0.7%) of the 141 patients. CONCLUSION: This computed tomography-based protocol proved to be reliable and hence can be considered as an adequate alternative to MRI-based stereotactic implantation if MRI is not available or if a single MRI-based stereotactic set-up is unreliable because of intolerable distortions.
机译:目的:提出一种基于计算机断层扫描的立体定向技术,用于海马内电极的纵向插入,并描述其准确性。方法:该技术利用了海马头上一个可很好再现的靶标和海马前后长度轴的近似倾斜度,以眼底为辅助标记。它被用于141例医学上难治的复杂部分性发作的患者。在106例患者中,磁共振成像(MRI)可用于评估植入的准确性。将212个电极中的每一个绘制在地形图上,并评定其贴合性。结果:海马头和身体分别被97%和96%的电极击中,而杏仁核仅被75%的电极击中,主要在其基底边缘。对于93%的电极,在矢状面内的倾斜度恰好与海马体的倾斜度相对应。植入的发病率为5.7%,而141例患者中有1例(0.7%)发生永久性神经功能缺损。结论:这种基于计算机断层扫描的协议被证明是可靠的,因此如果无法使用MRI或由于无法容忍的扭曲而无法基于MRI的单一立体定向设置,则可以认为它是基于MRI的立体定向植入的适当替代方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号