首页> 外文期刊>Medical Physics >Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE 125I brachytherapy source.
【24h】

Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE 125I brachytherapy source.

机译:IsoAid ADVANTAGE 125I近距离放射源剂量特性的实验和理论确定。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

125I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE 125I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98 +/- 0.03 cGy h(-1) U(-1). The radial dose function of the new source was measured in Solid Water and calculated both in water and Solid Water at distances up to 10.0 cm. The anisotropy function, F(r, theta), of the new source was measured and calculated in Solid Water at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE 125I source in water was found to be 0.97 +/- 0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper.
机译:125I近距离放射治疗源正在用于前列腺等肿瘤部位的间质植入物。最近,型号IAI-125的ADVANTAGE 125I来源可用于间质性近距离放射治疗。根据AAPM任务组43的建议,通过实验和理论确定了该源的剂量学特征(剂量率常数,径向剂量函数和各向异性函数)。剂量率常数的推导基于最近根据其1999年标准进行的NIST WAFAC校准。使用LiF热发光剂量计在Solid Water幻象中进行测量。使用PTRAN蒙特卡洛代码在固体水和水中都进行了理论计算。结果表明,新来源在水中的剂量率常数为0.98 +/- 0.03 cGy h(-1)U(-1)。在固体水中测量新源的径向剂量函数,并在水中和固体水中以10.0厘米的距离进行计算。在固体水中2 cm,3 cm,5 cm和7 cm的距离处测量并计算新源的各向异性函数F(r,theta),并且在1 cm至3 cm的距离处在水中也进行计算。距源7厘米。从各向异性函数推导出各向异性因子和各向异性常数。发现ADVANTAGE 125I源在水中的各向异性常数为0.97 +/- 0.03。与Amersham Health Model 6711来源的剂量特性相比,该新来源的剂量特性令人满意。本文介绍了新光源的完整剂量参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号