首页> 外文期刊>European Journal of Radiology >Observer variability of Breast Imaging Reporting and Data System (BI-RADS) for breast ultrasound.
【24h】

Observer variability of Breast Imaging Reporting and Data System (BI-RADS) for breast ultrasound.

机译:乳房超声检查的乳房成像报告和数据系统(BI-RADS)的观察者变异性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate inter- and intra-observer variabilities in breast sonographic feature analysis and management, using the fourth edition of the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS: We included 136 patients with 150 breast lesions who underwent breast ultrasound (US) and ultrasound-guided core needle biopsy. A pathological diagnosis was available for all 150 lesions: 77 (51%) malignant and 73 (49%) benign. Four radiologists retrospectively reviewed sonographic images of lesions twice within an 8-week interval. The observers described each lesion, using BI-RADS descriptors and final assessment. Inter- and intra-observer variabilities were assessed with Cohen's kappa statistic. Positive predictive value and negative predictive value (NPV) for final assessment were also calculated. RESULTS: For inter-observer agreements for sonographic descriptors, substantial agreement for lesion calcification and final assessment (kappa=0.61 for both), moderate agreement for lesion shape, orientation, boundary, and posterior acoustic features (kappa=0.49, 0.56, 0.59, and 0.49, respectively), and fair agreement for lesion margin and echo pattern (kappa=0.33 and 0.37, respectively) were obtained. For intra-observer agreement, substantial to perfect agreement was found for almost all lesion descriptors and final assessments. NPV for final assessment category 3 was 95%. Positive predictive value (PPV) for final assessment categorized as 4 or 5 were as follows: category 4a, 26%; category 4b, 89%; category 4c, 90%; and category 5, 97%. CONCLUSION: Because inter- and intra-observer agreement with the BI-RADS lexicon for US is good, the use of BI-RADS lexicon can provide accurate and consistent description and assessment for breast US.
机译:目的:使用第四版《乳腺成像报告和数据系统》(BI-RADS)评估观察者之间和观察者内部的乳房超声特征分析和管理差异。材料与方法:我们纳入了136例150例乳腺病变的患者,他们接受了乳房超声检查和超声引导下的穿刺活检。可以对所有150个病变进行病理诊断:77个(51%)恶性和73个(49%)良性。四位放射科医生在8周的间隔内两次回顾性检查了病变的超声图像。观察者使用BI-RADS描述符和最终评估描述了每个病变。观察者之间和观察者内部的变异性通过Cohen的kappa统计量进行评估。还计算了最终评估的阳性预测值和阴性预测值(NPV)。结果:对于观察者之间的超声描述符协议,病变钙化和最终评估(两者的kappa = 0.61)基本一致,病变形状,方向,边界和后声学特征的一致性中等(kappa = 0.49、0.56、0.59,和分别为0.49和0.49),并获得了病变边缘和回声模式的公平协议(kappa分别为0.33和0.37)。对于观察者内部协议,几乎所有病变描述词和最终评估结果均达到了实质性至完美的一致性。最终评估类别3的NPV为95%。归类为4或5的最终评估的阳性预测值(PPV)如下:4a类,26%; 4b类,89%;类别4c,90%;和5类,占97%。结论:由于观察者之间和内部与BI-RADS词典的协议良好,因此使用BI-RADS词典可以为美国乳腺癌提供准确,一致的描述和评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号