Objectives: The study aimed at determination of the usefulness of the subjective assessment of selected signs of fungi growth in flats and microclimate parameters to indicate the actual air contamination with culturable fungi, (1 -> 3)-beta-D-glucans and fungal spores. Material and Methods: This analysis covered 22 flats, the inhabitants of which declared in a questionnaire interview the presence of the developed mycelium on solid surfaces in the flat. Air samples for determination of the culturable fungi, (1 -> 3)-beta-D-glucans and (viable and non-viable) fungal spores concentrations indoor and outdoor the flats during the heating period were collected. During bioaerosol sampling microclimate parameters were measured. Predictive models for concentrations of the tested biological agents with regard to various ways to assess fungal contamination of air in a flat (on the basis of a questionnaire or a questionnaire and microclimate measurements) were built. Results: The arithmetic means of temperature, relative humidity, CO2 concentration and air flow velocity in the flats were respectively: 20.5 degrees C, 53%, 1431.6 ppm and 0 m/s. The geometric mean concentrations of airborne fungi, (1 -> 3)-beta-D-glucans and fungal spores in these premises amounted to 2.9 x 10(2) cfu/m(3), 1.6 ng/m(3) and 5.7 x 10(3) spores/m(3), respectively. The subjective assessment of fungi growth signs and microclimate characteristics were moderately useful for evaluation of the actual airborne fungi and (1 -> 3)-beta-D-glucan concentrations (maximum percent of explained variance (VE) = 61% and 67%, respectively), and less useful in evaluation of the actual fungal spore concentrations (VE < 29%). In the case of fungi, higher usefulness was indicated of the questionnaire evaluation supported by microclimate measurements (VE = 61.2%), as compared to the evaluation only by means of a questionnaire (VE = 46.9%). Conclusions: Subjective evaluation of fungi growth signs in flats, separately or combined with microclimate measurements, appeared to be moderately useful for quantitative evaluation of the actual air contamination with fungi and their derivatives, but more extensive studies are needed to strengthen those findings.
机译:目的:该研究旨在确定主观评估单位真菌生长迹象和微气候参数的有用性,以表明可培养真菌,(1-> 3)-β-D-葡聚糖和真菌孢子对实际空气的污染。材料和方法:该分析涵盖22个公寓,其中居民在调查表中声明对公寓中固体表面上存在的菌丝体进行了调查。收集用于确定加热期间室内和室外单位中可培养真菌,(1-> 3)-β-D-葡聚糖和(有活力和无活力)真菌孢子浓度的空气样品。在生物气溶胶采样期间,测量了微气候参数。建立了关于评估公寓中空气中真菌污染的各种方法的被测生物制剂浓度的预测模型(基于问卷或问卷以及微气候测量)。结果:公寓中温度,相对湿度,CO2浓度和空气流速的算术平均值分别为:20.5摄氏度,53%,1431.6 ppm和0 m / s。这些场所中的空气传播真菌,(1-> 3)-β-D-葡聚糖和真菌孢子的几何平均浓度分别为2.9 x 10(2)cfu / m(3),1.6 ng / m(3)和5.7 x 10(3)孢子/ m(3)。对真菌生长迹象和微气候特征的主观评估对于评估实际的空气传播真菌和(1-> 3)-β-D-葡聚糖浓度(解释差异的最大百分比(VE)= 61%和67%,分别),并且在评估实际真菌孢子浓度(VE <29%)方面不太有用。就真菌而言,与仅通过问卷调查进行评估(VE = 46.9%)相比,由小气候测量支持的问卷调查评估(VE = 61.2%)具有更高的实用性。结论:单独或与小气候测量相结合来对公寓中真菌的生长迹象进行主观评估似乎对于定量评估实际的真菌及其衍生物的空气污染有一定的帮助,但是需要进一步的研究以加强这些发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号