首页> 外文期刊>Intensive care medicine >Safety and efficacy of a fully closed-loop control ventilation (IntelliVent-ASV?) in sedated ICU patients with acute respiratory failure: a prospective randomized crossover study.
【24h】

Safety and efficacy of a fully closed-loop control ventilation (IntelliVent-ASV?) in sedated ICU patients with acute respiratory failure: a prospective randomized crossover study.

机译:镇静性ICU急性呼吸衰竭患者的全闭环控制通气(IntelliVent-ASV?)的安全性和有效性:一项前瞻性随机交叉研究。

获取原文
获取原文并翻译 | 示例

摘要

IntelliVent-ASV(?) is a development of adaptive support ventilation (ASV) that automatically adjusts ventilation and oxygenation parameters. This study assessed the safety and efficacy of IntelliVent-ASV(?) in sedated intensive care unit (ICU) patients with acute respiratory failure.This prospective randomized crossover comparative study was conducted in a 12-bed ICU in a general hospital. Two periods of 2 h of ventilation in randomly applied ASV or IntelliVent-ASV(?) were compared in 50 sedated, passively ventilated patients. Tidal volume (V(T)), respiratory rate (RR), inspiratory pressure (P(INSP)), SpO(2) and E(T)CO(2) were continuously monitored and recorded breath by breath. Mean values over the 2-h period were calculated. Respiratory mechanics, plateau pressure (P(PLAT)) and blood gas exchanges were measured at the end of each period.There was no safety issue requiring premature interruption of IntelliVent-ASV(?). Minute ventilation (MV) and V(T) decreased from 7.6 (6.5-9.5) to 6.8 (6.0-8.0) L/min (p < 0.001) and from 8.3 (7.8-9.0) to 8.1 (7.7-8.6) mL/kg PBW (p = 0.003) during IntelliVent-ASV(?) as compared to ASV. P(PLAT) and FiO(2) decreased from 24 (20-29) to 20 (19-25) cmH(2)O (p = 0.005) and from 40 (30-50) to 30 (30-39) % (p < 0.001) during IntelliVent-ASV(?) as compared to ASV. RR, P(INSP), and PEEP decreased as well during IntelliVent-ASV(?) as compared to ASV. Respiratory mechanics, pH, PaO(2) and PaO(2)/FiO(2) ratio were not different but PaCO(2) was slightly higher during IntelliVent-ASV(?) as compared to ASV.In passive patients with acute respiratory failure, IntelliVent-ASV(?) was safe and able to ventilate patients with less pressure, volume and FiO(2) while producing the same results in terms of oxygenation.
机译:IntelliVent-ASV(?)是自适应支持通气(ASV)的开发,可自动调节通气和充氧参数。这项研究评估了IntelliVent-ASV(?)在有急性呼吸衰竭的镇静重症监护病房(ICU)患者中的安全性和有效性。这项前瞻性随机交叉比较研究是在一家综合医院的12张病床的ICU中进行的。在50例有镇静,被动通气的患者中比较了随机应用的ASV或IntelliVent-ASV(?)中两个为时2小时的通气时间。持续监测潮气量(V(T)),呼吸频率(RR),吸气压力(P(INSP)),SpO(2)和E(T)CO(2),并记录呼吸频率。计算了2小时内的平均值。在每个周期结束时测量呼吸力学,平台压(P(PLAT))和血气交换。不存在需要提前中断IntelliVent-ASV(?)的安全问题。分钟通气量(MV)和V(T)从7.6(6.5-9.5)升至6.8(6.0-8.0)L / min(p <0.001)和从8.3(7.8-9.0)升至8.1(7.7-8.6)mL / min与ASV相比,在IntelliVent-ASV(?)期间,kg PBW(p = 0.003)。 P(PLAT)和FiO(2)从24(20-29)降至20(19-25)cmH(2)O(p = 0.005)和从40(30-50)降至30(30-39)%与ASV相比,在IntelliVent-ASV(?)期间(p <0.001)。与ASV相比,在IntelliVent-ASV(?)期间RR,P(INSP)和PEEP也下降。与ASV相比,IntelliVent-ASV(?)期间的呼吸力学,pH,PaO(2)和PaO(2)/ FiO(2)比率没有差异,但PaCO(2)略高。 ,IntelliVent-ASV(?)是安全的,能够为具有较小压力,体积和FiO(2)的患者通风,同时在充氧方面产生相同的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号