首页> 外文期刊>Analytical methods >A comparison of one-dimensional and microscale two-dimensional liquid chromatographic approaches coupled to high resolution mass spectrometry for the analysis of complex samples
【24h】

A comparison of one-dimensional and microscale two-dimensional liquid chromatographic approaches coupled to high resolution mass spectrometry for the analysis of complex samples

机译:一维和微型二维液相色谱方法与高分辨率质谱联用用于分析复杂样品的比较

获取原文
获取原文并翻译 | 示例
           

摘要

The interest in two-dimensional liquid chromatography separations is growing every year together with the number of open questions on the benefits of multidimensional systems in comparison to one-dimensional liquid chromatography. In order to solve some of these open questions this work presents a comparison of one-dimensional and microscale two-dimensional liquid chromatography coupled to high resolution mass spectrometry for targeted analysis in wastewater. The comparison is based on the evaluation of a reference standard mixture containing 99 compounds and a real wastewater sample. For the evaluation and compound identification three different criteria were chosen. At first, a deviation of +/- 5 ppm from the exact mass was defined as acceptable to include the compound for further evaluation. To eliminate false positive results, a maximum retention time deviation of less than 2.5% for each compound of the reference standard and the compounds detected in the wastewater sample was defined for a positive identification as a second criterion for 1D-LC and the second dimension of 2D-LC. In the third step, fragment information from MS/MS experiments was used for further identification of compounds in wastewater. Additionally, the influence of a higher mass accuracy of 1 ppm on the number of identified compounds in comparison to a mass accuracy of 5 ppm was investigated. The results showed that the number of identified compounds was higher by a factor of three in the wastewater sample when using the microscale 2D-LC approach. Moreover, a higher reliability for compound identification is obtained when using retention time and MS/MS information as identification criteria instead of only applying high mass accuracy of 1 or 5 ppm.
机译:与一维液相色谱法相比,二维液相色谱分离的兴趣每年都在增长,有关多维系统优势的悬而未决的问题也越来越多。为了解决这些悬而未决的问题,这项工作提出了将一维和微型二维液相色谱与高分辨率质谱联用进行废水中目标分析的比较。比较是基于对包含99种化合物和实际废水样品的参考标准混合物的评估。为了进行评估和化合物鉴定,选择了三个不同的标准。首先,将与精确质量的+/- 5 ppm的偏差定义为可接受,以包括用于进一步评估的化合物。为消除假阳性结果,定义了参考标准品的每种化合物和废水样品中检测到的化合物的最大保留时间偏差小于2.5%,以便将其作为1D-LC的第二标准和样品的第二维进行阳性鉴定。二维液相色谱第三步,将来自MS / MS实验的碎片信息用于进一步鉴定废水中的化合物。另外,研究了相对于5 ppm的质量精度,较高的1 ppm的质量精度对所识别化合物的数量的影响。结果表明,使用微型二维液相色谱方法时,废水样品中鉴定出的化合物数量增加了三倍。此外,当使用保留时间和MS / MS信息作为识别标准,而不是仅应用1或5 ppm的高质量精度时,可以获得更高的化合物识别可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号