...
首页> 外文期刊>Journal of the mechanical behavior of biomedical materials >A study of the reproducibility and reliability of the musculo-articular stiffness of the ankle joint
【24h】

A study of the reproducibility and reliability of the musculo-articular stiffness of the ankle joint

机译:踝关节肌关节刚度的再现性和可靠性研究

获取原文
获取原文并翻译 | 示例

摘要

The objective of this work was to evaluate the reproducibility, reliability and usefulness of the musculo-articular stiffness (MAS) of the ankle joint, measuring it by the free vibration technique. Seventeen (nine males and eight females) healthy university students were included in the study. Force (f), MAS (k) and unitary MAS (k(u)) (defined as the ratio between the value of stiffness k obtained in the test (absolute terms) and the value of force (f)) were obtained. A test-retest protocol was designed and performed on the same day to determine the short-term reproducibility off, k and k(u). Short-term reproducibility of k and ku on 1 day in absolute terms ( 7% Coefficient of Variation (CV)) and relative reproducibility (Intraclass Correlation Coefficient (ICC) and Pearson = 0.97) for both feet were obtained. The reliability of k and ku in absolute terms ( 9% CV) and in relative terms (ICC and Pearson = 0.93) based on repeating the protocol for 1 week was analysed for both feet. To analyse the usefulness, the Effect Size (ES) ratio = "Trivial" for all variables (for 1 day and 1 week) and the Smallest Worthwhile Change (SWC) ratio (Typical Error (TE) SWC) = "GOOD" for k and k (1 day and 1 week) were considered. The Minimal Difference needed to be considered "real" (MD) for k(u) congruent to 3.5% (1 day); k(u) congruent to 8.5% (1 week) (p 0.05) was obtained. The statistical analysis carried out displayed the high reproducibility, reliability and usefulness of the MAS test, which was more consistent with ku than k. Therefore, the unitary stiffness (k(u)) proven to be representative of the mechanical response of the ankle joint obtained by free vibration techniques, which allows comparison between different subjects.
机译:这项工作的目的是评估踝关节的肌肤关节刚度(MAS)的再现性,可靠性和有用性,通过自由振动技术测量它。第十七个(九月和八个女性)健康的大学生被包括在研究中。获得力(F),MAS(k)和单一的MAs(K(u))(定义为在试验中获得的刚度K之间的比率(绝对术语)和力(F)的值)。在同一天设计并执行测试重新测试,以确定短期再现性,K和K(U)。在绝对术语中1天的K和Ku的短期再现性(患者的1天(& 7%(cv))和双脚的相对再现性(ICC)和Pearson& = 0.97)。基于重复该协议的k和Ku在绝对术语(& 9%cv)和相对术语(ICC和Pearson& = 0.93)的可靠性进行了分析。为了分析有用性,所有变量的效果大小=“微不足道”(1天和1周)和最小的有价值变化(SWC)比率(典型的误差(TE)& swc)=“好”考虑K和K(1天和1周)。 k(u)一致为3.5%(1天)所需的“真实”(MD)所需的最小差异; K(U)一致地获得8.5%(1周)(P <0.05)。进行的统计分析显示了MAS测试的高再现性,可靠性和有用性,与KU比K更符合K.因此,已经证明的整体刚度(K(U))代表通过自由振动技术获得的踝关节的机械响应,这允许在不同受试者之间进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号