首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Validity and inter-day reliability of a free-oscillation test to measure knee extensor and knee flexor musculo-articular stiffness
【24h】

Validity and inter-day reliability of a free-oscillation test to measure knee extensor and knee flexor musculo-articular stiffness

机译:自由振动试验测量膝伸肌和膝屈肌肌关节僵硬度的有效性和日间可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to assess the validity and inter-day reliability of musculo-articular stiffness (MAS) in the knee-extensor (KE) and knee-flexor (KF) muscle groups, measured with a free-oscillation technique. Fourteen participants were measured, on two occasions, for KE and KF maximal isometric voluntary contraction, rate of torque development (RTD) and electromechanical delay (EMD), along with MAS using multiple sub-maximal loads relative to the individual's maximal voluntary contraction (MAS_(%MVC)). Furthermore, 18 participants were tested for MAS using one fixed assessment load for each muscle group (MAS_(FL)) during a separate series of tests on three occasions. MAS_(%MVC) was significantly increased as load increased both in KE and in KF (p<0.01) fitting a curvilinear relationship as depicted in similar studies. Validity was demonstrated relating MAS_(%MVC) to RTD (r=0.51-0.71, p<0.05) and to EMD (r=-0.56 to -0.67, p<0.05). While MAS%MVC reliability (ICC=0.62-0.89; CV=8.1-13.1%) was questionable to acceptable, MASFL exhibited good to excellent reliability (ICC=0.81-0.94; CV=3.7-6.5%). No significant systematic bias was detected for any of the variables considered. The assessment of KE and KF MAS using the free-oscillation technique appears to be valid and reliable, with the use of MAS_(FL) yielding higher reliability than the use of MAS_(%MVC).
机译:这项研究的目的是评估使用自由振荡技术测量的膝伸肌(KE)和膝屈肌(KF)肌肉群的肌肉-关节僵硬度(MAS)的有效性和日间可靠性。两次测量了14名参与者的KE和KF最大等距自主收缩,扭矩发展率(RTD)和机电延迟(EMD)以及MAS使用相对于个人最大自主收缩的多个次最大负荷(MAS_ (%MVC))。此外,在三种情况下分别进行的一系列测试中,对每个肌肉组(MAS_(FL))使用一个固定的评估负荷对18名参与者进行了MAS测试。在相似的研究中,随着KE和KF中的负荷增加,MAS _(%MVC)显着增加(p <0.01),符合曲线关系。证明了MAS _(%MVC)与RTD(r = 0.51-0.71,p <0.05)和EMD(r = -0.56至-0.67,p <0.05)的有效性。尽管MAS%MVC的可靠性(ICC = 0.62-0.89; CV = 8.1-13.1%)值得怀疑,但MASFL表现出良好至极好的可靠性(ICC = 0.81-0.94; CV = 3.7-6.5%)。对于所考虑的任何变量,均未检测到明显的系统偏差。使用自由振荡技术对KE和KF MAS的评估似乎是有效和可靠的,与使用MAS _(%MVC)相比,使用MAS_(FL)产生更高的可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号