首页> 外文期刊>American journal of dentistry >Effect of an 8.0% arginine and calcium carbonate in-office desensitizing paste on the microtensile bond strength of self-etching dental adhesives to human dentin
【24h】

Effect of an 8.0% arginine and calcium carbonate in-office desensitizing paste on the microtensile bond strength of self-etching dental adhesives to human dentin

机译:8.0%精氨酸和碳酸钙的办公室脱敏糊剂对自蚀刻牙科粘合剂与人牙本质的微拉伸粘合强度的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To evaluate in the laboratory the effect of an 8.0% arginine and calcium carbonate desensitizing paste in occluding open dentin tubules and examine the effect of bonding between the adhesive agents and dentin after being treated with the desensitizing paste. Methods: Two self-etching adhesives were used. Intact human premolars extracted for orthodontic reasons were used within 3 months of extraction. The occlusal enamel was removed and dentin slices were polished. The dentin tubules were opened by etching with a 1% citric acid solution for 20 seconds to simulate a postoperative sensitivity model. Then the specimens were randomly assigned into five groups. Group A: specimens without any treatment (control). Group B: specimens were polished with a slurry (SiO 2) for 30 seconds. Groups C, D and E: 8.0% arginine and calcium carbonate desensitizing paste was applied. Specimens in Group C were polished for 3 seconds, and then repeated for another 3 seconds for a total of 6 seconds, according to the manufacturer's instructions: specimens in Group D were polished twice for 9 seconds for a total of 18 seconds; and specimens in Group E were treated for an extended time of 30 seconds. Each group was randomly divided into two sub-groups in order to evaluate the effect on two diffedhesive agents. A one-step self-etching adhesive agent (G-Bond) and a two-step self-etching adhesive agent (Fl-Bond II) were applied following the manufacturers' instructions. Then microtensile bond strengths of the 10 groups were tested. SEM was used to evaluate the laboratory effect of the desensitizing paste in occluding open dentin tubules. Statistical analysis was carried out using SPSS version 16.0. Results: The SEM observations showed that the 8.0% arginine and calcium carbonate desensitizing paste could occlude the dentin tubules effectively, and thus may have potential benefits in preventing postoperative sensitivity based on the hydrodynamic theory. An extended application time of 18 or 30 seconds showed no adverse effect of the desensitizing paste on the bonding performance to dentin when using self-etching adhesives containing functional monomers such as 4-MET like G-Bond.
机译:目的:在实验室中评估8.0%的精氨酸和碳酸钙脱敏糊剂在封闭开放性牙本质小管中的作用,并检查脱敏糊剂处理后粘合剂与牙本质之​​间的粘合效果。方法:使用两种自蚀刻粘合剂。由于正畸原因提取的完整人类前磨牙在提取后3个月内使用。去除牙釉质并抛光牙本质切片。通过用1%柠檬酸溶液蚀刻20秒来打开牙本质小管,以模拟术后敏感性模型。然后将标本随机分为五组。 A组:未经任何处理的标本(对照)。 B组:将样品用浆料(SiO 2)抛光30秒。 C,D和E组:施加8.0%的精氨酸和碳酸钙脱敏膏。根据制造商的说明,将C组中的样品抛光3秒,然后再重复3秒,共6秒钟:D组中的样品抛光两次,共9秒,共18秒; E组的标本经过30秒的延长处理。为了评估对两种扩散剂的作用,将每组随机分成两个亚组。按照制造商的说明使用一步自蚀刻胶(G-Bond)和两步自蚀刻胶(Fl-Bond II)。然后测试了10组的微拉伸粘合强度。 SEM用于评估脱敏膏在封闭开放式牙本质小管中的实验室效果。使用SPSS 16.0版进行统计分析。结果:扫描电镜观察表明,8.0%的精氨酸和碳酸钙脱敏膏可以有效地阻塞牙本质小管,因此根据流体力学理论可能具有预防术后敏感性的潜在益处。当使用含有功能性单体(如4-MET的G-Bond)的自蚀刻胶粘剂时,延长的18或30秒的施加时间不会显示脱敏浆料对牙本质粘合性能的不利影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号