H'/> A simple and fast LC–MS/MS method with a very high sensitivity for the measurement of raltitrexed in human plasma
首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >A simple and fast LC–MS/MS method with a very high sensitivity for the measurement of raltitrexed in human plasma
【24h】

A simple and fast LC–MS/MS method with a very high sensitivity for the measurement of raltitrexed in human plasma

机译:一种简单而快速的LC-MS / MS方法,具有非常高的人体血浆中罗尔特拉特的灵敏度

获取原文
获取原文并翻译 | 示例
           

摘要

Highlights ? Patients display very low and high concentrations after Raltitrexed administration. ? Current methods don’t allow to simultaneously measure such concentrations. ? We present a simple and fast method to measure these concentrations in a single run. ? Sample preparation is limited to acetonitrile precipitation and captiva? filtration. ? This method is validated following EMA guidelines. Abstract Raltitrexed is a thymidylate synthase inhibitor that can be administered safely to patients with cardiovascular disease or dihydropyrimidine dehydrogenase deficiency, as opposed to 5FU. The recommended dose of 3mg/m2 every 3 weeks often leads to toxicity. Interestingly, the 2mg/m2 every 2 weeks dose appears to be less toxic. A pharmacokinetic trial was then performed by our team to investigate such phenomenon. However, there are currently, two main methods for RTX measurement described in the literature: a radioimmunoassay (RIA) and chromatographic-based methods with either UV or mass spectrometry detections. The RIA methods: display a low limit of quantification (below 1μg/L), but also a low extent of linearity for the calibration curve. The chromatographic-based methods: include high level of calibrators, but have poor sensitivity (2μg/mL). If a high sensitivity is essential to satisfactorily describe the elimination of RTX, high concentrations in the calibration curve are also needed to avoid bias linked to the dilutions of the samples. A new LC–MS/MS method was then developed that allows to simultaneously measure very low (0.1μg/L) and very high (3000μg/L) concentrations in the same run. Moreover, the extraction steps are very simple and fast with mainly a precipitation and a filtration steps. This method was validated following the EMA recommendations. In view of the extent of the calibration curve, the carry-over effect was more deeply investigated. With this method, it was possible to measure RTX in samples taken 3 weeks after the administration. Taken together, this method allows to simply and quickly measure RTX in plasma of patients.
机译:<![cdata [ 突出显示 患者在罗尔特拉特施用给药后显示出非常低浓度和高浓度。 当前方法不允许同时测量这种浓度。 我们提出了一种简单而快速的方法来单一运行测量这些浓度。 SA Mple制备仅限于乙腈沉淀和Captiva 过滤。 此方法在EMA指南下验证。 抽象 roltitrexed是胸糊糊的合成酶抑制剂可以安全地给予心血管疾病或二氢嘧啶脱氢酶缺乏症的患者,而不是5Fu。推荐剂量为3 mg / m 2 每3周常常导致毒性。有趣的是,2 mg / m 2 每2周剂量似乎减少毒性。然后由我们的团队进行药代动力学试验来调查这种现象。然而,目前,文献中描述的两种主要方法是RTX测量:具有UV或质谱检测的放射免疫测定(RIA)和基于色谱的方法。 RIA方法:显示量化的低限制(低于1 μg/ L),但也为校准曲线的线性度的低程度。基于色谱的方法:包括高水平的校准剂,但敏感性差(& 2 μg/ ml)。如果高灵敏度对于令人满意地描述消除RTX,则还需要校准曲线中的高浓度以避免与样品的稀释液连接的偏差。然后开发出一种新的LC-MS / MS方法,其允许同时测量非常低(0.1 μg/ L)并且非常高(3000 μg/ L)浓度相同的运行。此外,提取步骤非常简单,快速,主要是沉淀和过滤步骤。在EMA建议后验证了该方法。鉴于校准曲线的程度,更深入地研究了随身效应。通过这种方法,可以在给药后3周服用样品中测量RTX。在一起,这种方法允许简单快速地测量患者血浆中的RTX。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号