首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Ionization study and simultaneous determination of avermectins and milbemycines in fish tissue by LC-ESI-MS/MS
【24h】

Ionization study and simultaneous determination of avermectins and milbemycines in fish tissue by LC-ESI-MS/MS

机译:LC-ESI-MS / MS的离子化研究及鱼组织中Avermectins和Milbemycines的同时测定

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, the simultaneous determination of avermectins (emamectin, eprinomectin, abamectin, doramectin and ivermectin) and milbemycines (moxidectin) in fish tissue with LC-ESI-MS/MS, was studied. Optimum chromatographic separation of target analytes was achieved using a Waters Acquity UPLC BEH C-18 (100 mm x 2.1 mm, 1.7 mm) analytical column, operated at 40 degrees C and the composition of the mobile phase used was (A): ACN-MeOH (0.1% HCOOH) (1:1) and (B): 1 mM HCOONH4 (0.1% HCOOH). Various mobile phases were tested and the effect of the mobile phase composition on the analytes ionization was thoroughly examined in an extensive ionization study, aiming to increase the analytes' sensitivity. Deuterated ivermectin (IVR-d(2)) was used as an internal standard (IS). Avermectins and milbemycine's extraction from the fish matrix was conducted with acidified ACN (0.1% HCOOH), followed by QuEChERS methodology. The method developed herein was validated according to the European Legislation requirements (Commission Decision 657/2002/EC) and recoveries ranged from 86 to 106% for all target analytes, with relative standard deviations 20%. LODs ranged from 0.07 mu g/kg (emamectin) to 1.3 mu g/kg (doramectin), indicating the excellent sensitivity of the method. The developed methodology was successfully applied to fish samples obtained from aquaculture.
机译:在该研究中,研究了与LC-ESI-MS / MS的鱼组织中的Avermectins(evamectin,ePrinecectin,Abamectin,Doramectin和Ivermectin)和Milbemycines(Moxidectin)的同时测定。使用水的近期UPLC BEH C-18(100mm×2.1mm,1.7mm)分析柱,在40摄氏度下操作,使用的流动相的组成是(a)的组成,实现了靶分析物的最佳色谱分离MeOH(0.1%HCOOH)(1:1)和(B):1mM HCOOHH4(0.1%HCOOH)。测试各种流动相,在广泛的电离研究中彻底检查了流动相组合物对分析物电离的影响,旨在提高分析物的敏感性。氘代Ivermectin(IVR-D(2))用作内标(是)。 Avermectins和Milbemycine从鱼基质的提取用酸化的AcN(0.1%HCOOH)进行,然后是QueChers方法。根据欧洲立法要求(委员会第657/2002 / EC)和所有目标分析物的回收率验证了此处的方法,以及相对标准偏差的回收率范围为86至106%。 20%。 LOD范围为0.07μg/ kg(萃取蛋白)至1.3μg/ kg(多样素),表明该方法的优异敏感性。开发方法已成功应用于从水产养殖中获得的鱼类样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号