首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Analysis of procedural data of pulmonary vein isolation for atrial fibrillation with the second‐generation laser balloon
【24h】

Analysis of procedural data of pulmonary vein isolation for atrial fibrillation with the second‐generation laser balloon

机译:第二代激光球囊肺静脉隔离肺静脉分离的程序数据分析

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background The procedural data of pulmonary vein (PV) isolation (PVI) for patients with atrial fibrillation using the second‐generation laser balloon (LB2), which became available recently, remains unclear and were evaluated. Methods Thirty consecutive patients (116 PVs) underwent PVI using LB2 (LB2 group) and were matched to 30 patients (116 PVs) treated with the first‐generation laser balloon (LB1 group). The left atrial isolated surface area (ISA) (ratio of the total isolated antral surface area excluding PV to the total isolated antral surface area including the posterior wall) was also measured after LB2 PVI. Results PVI was achieved in 103/116 (89%) PVs and 108/116 (93%) PVs in the LB2 and LB1 groups, respectively, after the initial circular ablation (P?=?0.360) and in 115/116 (99%) PVs and 116/116 (100%) PVs in the LB2 and LB1 groups, respectively, at the end of the procedure (P?=?1.000). PV occlusion grade, categorized by the degree of PV occlusion, was significantly better in the LB2 group than in the LB1 group (P??0.001). Zero rotational maneuver was applicable in 23/116 (20%) PVs and 8/116 (7%) in the LB2 and LB1 groups, respectively (P?=?0.007). There was no significant difference in the procedural time, fluoroscopic time, or complications. The mean ISA after LB2 PVI was 53 ± 14%. The application number was the only independent predictor of successful PVI after initial circular LB2 ablation (adjusted odds ratio 0.860; 95% confidence interval 0.764–0.968; P?=?0.013). Conclusion LB2 displays favorable PV occlusion characteristics and enables more zero rotational maneuvers.
机译:摘要背景下,使用第二代激光球囊(LB2)的心房颤动患者的肺静脉(PV)隔离(PVI)的程序数据仍然不清楚并评估。方法采用LB2(LB2)(116级)进行PVI的30例连续患者(116PVs),并与第一代激光球囊(LB1组)处理的30名患者(116pVs)匹配。在LB2 PVI之后,还测量左心房隔离表面积(ISA)(除了PV上的总分离的Antral表面积与PV的总分离的腹部表面积)进行测量。结果在初始循环消融之后分别在103/116(89%)PVS和108/116(93%)PV中获得的108/116(93%)PV,并在初始循环消融(P?= 0.360)和115/116(99在步骤结束时分别在LB2和LB1组中PV和116/116(100%)PV(P?=?1.000)。 PV闭塞等级,通过PV闭塞程度进行分类,在LB2组中显着更好,而不是LB1基团(P≤≤0.001)。零旋转操纵分别适用于LB2和LB1组中的23/116(20%)PVS和8/116(7%)(P?= 0.007)。程序时间,荧光透视时间或并发症没有显着差异。 LB2 PVI后的平均ISA为53±14%。申请号是初始圆形LB2消融后成功PVI的唯一独立预测因子(调整后的差距0.860; 95%置信区间0.764-0.968; p?= 0.013)。结论LB2显示出有利的PV闭塞特性,可实现更零的旋转操纵。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号