...
首页> 外文期刊>Oral surgery, oral medicine, oral pathology oral radiology >Comparative analysis of imaging techniques for diagnostic accuracy of peri-implant bone defects: a meta-analysis
【24h】

Comparative analysis of imaging techniques for diagnostic accuracy of peri-implant bone defects: a meta-analysis

机译:围植入骨缺损诊断准确性成像技术的比较分析:META分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective The aim of this study was to systematically review the literature regarding diagnostic accuracy of imaging techniques in detecting peri-implant bone defects. Study Design The search was performed in 8 electronic databases from April to May 2016 and updated in September 2016. Studies that assessed imaging techniques to detect peri-implant bone defects were analyzed. Results The search yielded 680 articles published from 1991 to 2016. Of these, 12 studies were considered eligible for this review. The selected studies evaluated the use of cone beam computed tomography (CBCT), intraoral radiography (IR), computed tomography, and panoramic radiography. The sensitivity for CBCT was 59%, whereas the specificity was 67%. For IR, the sensitivity was 60%, and the specificity was 59%. Area under the curve values in receiver operating characteristic (ROC) analysis were 69% for CBCT and 63% for IR. For CBCT, the highest value for positive predictive value was 0.94, negative predictive value was 0.98, positive likelihood ratio was 21.3, and negative likelihood ratio was 1.28. For IR, the highest positive predictive value was 1.0, negative predictive value 1.0, positive likelihood ratio 50.0, and negative likelihood ratio 0.70. The highest diagnostic odds ratio was 80 for CBCT and 4.45 for IR. No conclusion could be drawn for additional techniques. Conclusions Both CBCT and IR showed a clinically acceptable performance for assessing peri-implant bone defects. ]]>
机译:目的本研究的目的是系统地审查关于检测PERI-植入骨缺陷的成像技术的诊断准确性的文献。研究设计搜索在2016年4月至2016年5月的8个电子数据库中进行,并于2016年9月更新。分析了检测PERI-植入骨缺损的成像技术的研究。结果搜索从1991年到2016年发布的680篇文章。其中,12项研究被认为是符合本综述的条件。所选择的研究评估了锥形光束计算机断层扫描(CBCT),内部射线照相(IR),计算机断层扫描和全景射线照相的使用。 CBCT的敏感性为59%,而特异性为67%。对于IR,敏感性为60%,特异性为59%。接收器的曲线值下的面积为CBCT的接收器特性(ROC)分析为69%,IR为63%。对于CBCT,阳性预测值的最高值为0.94,阴性预测值为0.98,阳性似然比为21.3,负可能性比为1.28。对于IR,最高的阳性预测值为1.0,负预测值1.0,阳性似然比50.0和负似然比0.70。最高诊断赔率比为CBCT和IR的4.45。无法为额外的技术进行结论。结论CBCT和IR两种CBCT和IR都显示出临床上可接受的性能,用于评估PERI-植入骨缺陷。 ]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号