首页> 外文期刊>Mikrochimica Acta: An International Journal for Physical and Chemical Methods of Analysis >A SERS-based multiple immuno-nanoprobe for ultrasensitive detection of neomycin and quinolone antibiotics via a lateral flow assay
【24h】

A SERS-based multiple immuno-nanoprobe for ultrasensitive detection of neomycin and quinolone antibiotics via a lateral flow assay

机译:基于SERS的多种免疫纳米孔,通过侧向流动测定超声检测新霉素和喹啉抗生素

获取原文
获取原文并翻译 | 示例
           

摘要

The authors describe an ultrasensitive method for simultaneous detection of neomycin (NEO) and quinolones antibiotics (QNS). It is based on the use of (a) two immuno-nanoprobes (a probe for NEO and a probe for QNS), (b) surface-enhanced Raman scattering (SERS) detection, and (c), a portable lateral flow assay (LFA). The two probes consist of gold nanoparticles (AuNPs) conjugated to the Raman active molecule 4-aminothiophenol (PATP), and to monoclonal antibody against NEO (NEO mAb) or against NOR (NOR mAb). Quantitative detection of NEO and QNS was realized via SERS of the PATP-coated AuNPs captured in the test line of a LFA. Under optimized condition, the visual limits of LFA are 10 ng.mL(-1) for NEO and 200 ng.mL(-1) for NOR, and with LODs down to 0.37 pg.mL(-1) and 0.55 pg.mL(-1) by using SERS. The NEO test line is not interfered by the NEO analogues gentamycin, streptomycin and tobramycin, but the NOR test line suffers from different degrees of cross-reactivity (CR) to 12 common other QNS, the CRs ranging from 1.5% to 136%. The recoveries of NEO and NOR from spiked milk samples ranged between 86% and 121%, with relative standard deviations (RSD) from 3% to 6%. The method is highly sensitive, accurate and effective. It may be applied to simultaneous detection of NEO and 8 QNS, including NOR, enoxacin, ciprofloxacin, ofloxacin, fleroxacin, marbofloxacin, enrofloxacin, and pefloxacin.
机译:作者描述了一种超细敏感方法,用于同时检测新霉素(Neo)和喹诺酮抗生素(QNS)。它基于(a)两种免疫纳米体(探针的探针和QNS的探针),(b)表面增强拉曼散射(sers)检测,(c),便携式横向流动测定( LFA)。这两种探针由与拉曼活性分子4-氨基噻吩(PatP)缀合的金纳米颗粒(AUNP)组成,对NOO(Neo MAb)的单克隆抗体或抗(NOR MAB)组成。通过在LFA的测试线中捕获的Patp涂覆的AUNPS的SERS来实现NEO和QN的定量检测。在优化条件下,LFA的视觉限制为NeO和200ng.ML(-1)的10ng.ML(-1),也不是下降至0.37pg.ml(-1)和0.55 pg.ml的LOD (-1)使用sers。 Neo类似物庆大霉素,链霉素和染发霉素的NEO测试线不会干扰,但是测试线的患者患有不同程度的交叉反应性(CR)至12个常见的其他QN,CRS的范围为1.5%至136%。 NeO和掺入牛奶样品的回收率范围为86%至121%,相对标准偏差(RSD)从3%到6%。该方法具有高敏感,准确有效。它可以应用于同时检测Neo和8 QNS,包括NOR,Enoxacin,CiProfloxacin,α氧氟辛林,Fleroxacin,马尔巴福氟苯胺,苯甲酰克罗那和Pefloxacin。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号