首页> 外文期刊>European journal of clinical microbiology and infectious diseases: Official publication of the European Society of Clinical Microbiology >Performance of a new combination of blood culture vials in sepsis detection: a 2-year retrospective comparison
【24h】

Performance of a new combination of blood culture vials in sepsis detection: a 2-year retrospective comparison

机译:败血症检测中血液培养小瓶的新组合的性能:2年的回顾性比较

获取原文
获取原文并翻译 | 示例
           

摘要

The diagnosis of bloodstream infection requires the optimum combination of media in an automated blood culture system for maximum recovery of pathogens with the earliest time to detection. In a previous work, we showed that for patients admitted to the Emergency Department of our hospital, the combination of BACTEC lytic anaerobic and BACTEC aerobic vials was more efficient than BACTEC anaerobic and BACTEC aerobic vial. In this study, we extended the work including a broader patient population, representative of all hospital. A total of 8629 cultures were collected during the pre-lytic phase, from 01 July 2013 to 30 June 2014 and 7940 cultures during the post-lytic phase, ranged from 01 July 2015 to 30 June 2016. The number of positive blood cultures was higher during the post-lytic phase (19.74%) than in the pre-lytic phase (17.52%), particularly for Escherichia coli, Staphylococcus spp., Enterococcus spp., and anaerobes. We also observed a significant decreased of the time to detection, with the mean and median in the post-lytic phase of 17.68 and 13.05 h compared with 19.49 and 14.47 h in the pre-lytic phase. Whereas the time to detection was the same for organisms recovered in the aerobic Plus bottles for both time periods, time to detection for the anaerobic lytic bottles was significantly faster than with the anaerobic Plus bottles. This study carried out on a long time observation reported that a simple modification of composition of blood culture set could lead to better results in bloodstream infection detection.
机译:血流感染的诊断需要在自动血液培养系统中最佳的培养基组合,以最快地检测到病原体。在以前的工作中,我们表明,对于患者入住我们医院急诊部的患者,Bactec Lytic Anaerobic和Bactec Aerobic小瓶的组合比Bactec Anaerobic和Bactec Aerobic小瓶更有效。在这项研究中,我们延长了所有医院的更广泛的患者人口,包括更广泛的患者人口。在2013年7月01日至2014年6月30日至2014年6月30日和7940年6月30日期间,在2015年7月01日至2016年6月30日,共收集了8629份培养物。积极血液培养的数量较高在裂变后相(19.74%),比在裂变前相(17.52%),特别是对于大肠杆菌,葡萄球菌SPP。,肠球菌SPP。和厌氧菌。我们还观察到检测时间的显着降低,其在毛利期后的平均值和中值与预裂变相中的19.49和14.47小时相比。然而,对于在有氧加瓶中回收的生物体的检测时间相同,而在时间段中,厌氧裂解瓶的检测时间比厌氧加瓶的时间明显快。该研究在很长一段时间内进行了报道,血液培养集组成的简单改性可能导致血流感染检测的结果更好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号