首页> 外文期刊>Engineering Geology >Foundation evaluation of underground metro rail station using geophysical and geotechnical investigations
【24h】

Foundation evaluation of underground metro rail station using geophysical and geotechnical investigations

机译:地球物理学和地铁调查基础评价地铁地铁站

获取原文
获取原文并翻译 | 示例
           

摘要

Excavations for underground space developments in a thickly populated urban area are sometimes hindered by unexpected formidable consequences like formation of sinkholes or uneven settlement of foundations. Such troublesome incidences occasionally damage structures in the vicinity of excavations. Although adequate design guidelines and codes of practices are adopted, the disturbance of subsurface regime due to excavation or construction activities often leads to undesired stability issues with resultant appearance of weak zones. The reinforcement of weak zones by grouting is one of the common remedies, without demarcating the weak or the affected zones becomes counter-productive. Excavation at a location in Chennai mega-city for metro rail was severely affected by soil piping with development of sinkholes and weakening of the surrounding strata. Subsequently development of cracks in the adjacent buildings, and caused tilting of the nearby taller structures. The mandated the geophysical and geotechnical investigations were carried out to demarcate the affected area to avoid further deterioration of the site. Cross-hole seismic P- and S-wave velocities were estimated between10-pairs of boreholes up to 20 m depth on both the sides of the excavation. Two electrical resistivity tomography (ERT) profiles (each of 141 m in length) were carried out in the same location. Cross-hole S-wave velocity profiles and resistivity tomograms clearly indicate the presence of weak zones, and possible sinkhole locations. Site specific empirical relationship was established between S-wave velocity and standard penetration test (SPT) N-value. This relationship was further used for determination of SPT N-values from the measured Vs values to compare the subsurface conditions identified under pre- and post-excavations. The results confirmed the presence of weak zones, which are responsible for the weakening of the surrounding strata in the foundation. Geophysical and geotechnical investigations, similar to present investigation, can be useful for designing metro rail projects in a subsurface environment comprising alluvium, sand, clay mixed with silt, pebbles and boulders, lying near a region of ground water pocket in a thickly populated urban area.
机译:厚普利人口稠密的城市地区的地下空间开发的挖掘有时会受到意外的强大后果,如污水露或不均匀的基础结算。这种麻烦的事件偶尔会损坏挖掘附近的结构。尽管采用了适当的设计准则和实践守则,但由于挖掘或施工活动而导致的地下制度的干扰通常导致不希望的稳定性问题,弱区的出现。通过灌浆加强弱区是常见的补救措施之一,无需划分弱或受影响的区域变得反复效果。挖掘在钦奈Mega-City的地铁轨道的地点受到土壤管道的严重影响,具有下沉孔和周围地层的弱化。随后在相邻建筑物中开发裂缝,并引起附近的更高结构的倾斜。授权地球物理和岩土工程调查进行了划分受影响的区域,以避免该网站的进一步恶化。在挖掘的两侧估计交叉孔地震性P-和S波速度高达20米深度的井筒。两个电阻率断层扫描(ERT)轮廓(长度为141米)在同一位置进行。交叉孔S波速度分布和电阻率断层图像清楚地表明存在弱区,以及可能的污水孔位置。在S波速度和标准渗透试验(SPT)N值之间建立了特定的实证关系。这种关系进一步用于确定来自测量的VS值的SPT n值,以比较在预先开挖和后挖掘下识别的地下条件。结果证实存在弱区,这负责基础上的周围地层的弱化。类似于目前调查的地球物理和岩土工程调查,可用于在地下环境中设计地铁导轨项目,包括加油,沙子,粘土与淤泥,鹅卵石和巨石混合,躺在一个厚厚的城市地区的地下水袋附近。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号